The computation program of the transient recovery voltages that appears across the terminals of a circuit breaker, after the low inductive current has been interrupted at the disconnecting no load high voltage transformers, using the routines set developed in Matlab is presented. The computation algorithm is based on the peculiarities of operation of the transformer. The computation program has been applied for transformers from the high voltage electric stations ST North Craiova and ST Urechesti. The computed level of the overvoltage amplitude allows the proper selection of the rated insulation level of the electrical equipment from the electric stations.
منابع مشابه
Alternating Voltage Tests on Distribution Transformers Using Static Frequency Converters
This paper presents experience in performing alternating voltage measurements on distribution transformers using a static frequency converter without particular control scheme. Regarding induced voltage tests, no-load and load measurements, the quality, i.e. the degree of distortion and the symmetrical shape, of the generated test voltage, deviations in measured power and the relation between d...
متن کاملHigh-Voltage Resonant Converter with Extreme Load Variation: Design Criteria and Applications
The power converter that feeds high-frequency, highvoltage transformers must be carefully designed due to parasitic components, mainly the secondary winding capacitance and the leakage inductance, that introduces resonances in relatively lowfrequency range, next to the switching frequency. This paper considers applications in which the load (resistive) has an unpredictable behavior, changing fr...
متن کاملElectronic compensation of inductive voltage dividers and standard voltage transformers
A new compensating system is proposed to reduce the ratio error and the phase error of inductive voltage dividers and standard voltage transformers, operating at no load. An electronic amplifier reduces the input current, which is the main cause of error in low-frequency applications, while at the same time the input impedance is greatly increased.
متن کاملFrequency Tracking to Maximum Power of Piezoelectric Transformer HV Converters under Load Variations
The problem of maximum power point tracking of high output DC voltage converters that apply Piezoelectric Transformers (PT) and voltage doublers was studied theoretically and experimentally. It was shown that the operating frequency of the PT, at which maximum voltage gain is reached, is a function of the load. Hence, under load variations, and to overcome parameters instability, there is a nee...
متن کاملA Fast Voltage Collapse Detection and Prevention Based on Wide Area Monitoring and Control
Voltage stability is one of the most important factors in maintaining reliable operation of power systems. When a disturbance occurs in the power system, it usually causes instabilities and sometimes leads to voltage collapse (VC). To avoid such problems, a novel approach called Vector Analysis (VA) is proposed that exploits a new instability detection index to provide wide area voltage stabili...
متن کامل