Effect of pre-heating composite resin on gap formation at three different temperatures
نویسندگان
چکیده
AIM The study aims to evaluate and compare total gap surface area formed after restoration of class II cavities with Filtek Z350 and P60 at room temperature, 37°C and 54°C. MATERIALS AND METHODS Thirty extracted maxillary and mandibular molars were taken and divided into six groups of five teeth each. Standardized class II cavities were made and were restored with Filtek Z350 and P60, both at room temperature, 37°C and 54°C. Group 1(a) was restored with Filtek Z350 at room temperature, Group 1(b) with Filtek Z350 at 37°C and Group 1(c) with Filtek Z350 at 54°C. Group 2(a) was restored with P60 at room temperature, Group 2(b) with P60 at 37°C and Group 2(c) with P60 at 54°C. After storing the samples in distilled water at room temperature for 48 hours, longitudinal sectioning was done to obtain tooth restoration interface. The interfaces were then examined under compound light microscope with digital output and analyzed using Image J analysis software. RESULTS The results demonstrated better adaptation and less total gap area formation at 54°C as compared to room temperature and 37°C. CONCLUSIONS Based on the results of this study, it is suggested that use of P60 is better suited for posterior restorations at 54°C as compared to Filtek Z350 universal nanohybrid at room temperature.
منابع مشابه
Effect of Pre-heating on Microtensile Bond Strength of Composite Resin to Dentin
OBJECTIVE Direct composite resin restorations are widely used and the impact of different storage temperatures on composites is not well understood. The purpose of this study was to evaluate the microtensile bond strength of composite to dentin after different pre-curing temperatures. MATERIALS AND METHODS Occlusal surfaces of 44 human molars were ground with diamond burs under water coolant ...
متن کاملEffect of intermediate agents and pre-heating of repairing resin on composite-repair bonds.
This study investigated the composite-to-composite microtensile bond strength and interfacial quality after using different combinations of intermediate agents and pre-curing temperatures of repairing resin. Forty-five composite discs (8x4 mm) of Gradia Direct Anterior (GC Corp), stored in a saline solution at 37 degrees C for one month, were sandblasted (50 microm aluminum oxide), cleaned (35%...
متن کاملبررسی اثرکامپوزیت Light Cure و کامپوزیت Self Cure بر باندگلاس آینومر نوری به عاج دندان (In-vitro)
Statement of Problem: Composite reins have recently become popular for posterior teeth restorations. Gap formation and subsequent microleakage are of the complications resulting from such restorations. One of the techniques to overcome polymerization shrinkage of composite resins is sandwich technique (application of glass ionomer as a base beneath the composite resin). Since polymerization pat...
متن کاملPre-heating of high-viscosity bulk-fill resin composites: effects on shrinkage force and monomer conversion.
OBJECTIVES To investigate the influence of pre-heating of high-viscosity bulk-fill composite materials on their degree of conversion and shrinkage force formation. METHODS Four bulk-fill composite materials (Tetric EvoCeram Bulk Fill-TECBF, x-tra fil-XF, QuixFil-QF, SonicFill-SF) and one conventional nano-hybrid resin composite (Tetric EvoCeram-TEC) were used. The test materials were either k...
متن کاملAnalysis of Gap Formation at Tooth-composite Resin Interface: Effect of C-factor and Light-curing Protocol
OBJECTIVE The aim of this study was to evaluate the effect of C-factor and light-curing protocol on gap formation in composite resin restorations. MATERIAL AND METHODS Cylindrical cavities with 5.0 mm diameter and three different depths (A=1.0, B=2.0 and C=3.0 mm) were prepared on the occlusal surface of 30 human molars and restored in a single increment with P 60. The composite resin was lig...