Intensity-modulated radiotherapy using two static ports of tomotherapy for breast cancer after conservative surgery: dosimetric comparison with other treatment methods and 3-year clinical results

نویسندگان

  • Aiko Nagai
  • Yuta Shibamoto
  • Masanori Yoshida
  • Koji Inoda
  • Yuzo Kikuchi
چکیده

This study investigated the differences in dose-volume parameters for the breast and normal tissues during TomoDirectTM (TD) intensity-modulated radiation therapy (IMRT), TD-3D conformal radiotherapy (3DCRT) and 3DCRT plans, all using two beams, and analyzed treatment outcomes of two-beam TD-IMRT for breast cancer after breast-conserving surgery. Between August 2011 and January 2015, 152 patients were treated using two-beam TD-IMRT with 50 Gy/25 fractions. Among them, 20 patients with left-sided breast cancer were randomly chosen, and two-beam TD-IMRT, TD-3DCRT and 3DCRT plans were created for each patient. The homogeneity and conformity indices and various dose-volume parameters for the planning target volume and OARs were evaluated. Clinical outcomes were evaluated at 3 years. Toxicities were evaluated using the Common Terminology Criteria for Adverse Events version 4.0. TD-IMRT and TD-3DCRT showed better whole-breast coverage than 3DCRT (P < 0.001). Most of the mean values of dosimetric endpoints for OARs were better in TD-IMRT than in TD-3DCRT and 3DCRT. Overall survival rates were 97.7% and local control rates were 99.1% at 3 years. Regional control and distant metastasis control rates at 3 years were 98.6% and 96.8%, respectively. Twenty-four of the 152 patients had Grade 2 or higher acute radiation dermatitis. Four patients (4/146 = 2.7%) had Grade 2 radiation pneumonitis. There were no late adverse events of Grade 2 or higher. Two-beam TD-IMRT appeared to yield better dose distribution for whole-breast external-beam radiation therapy than TD-3DCRT and two-beam 3DCRT. The treatment appeared to provide low skin toxicity and acceptable tumor control.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of dosimetric radiotherapy of whole left- breast cancer using conventional tangential wedge-based techniques (CTT) and three intensity modulation techniques (IMRT)

Introduction: Whole breast radiotherapy after breast-conserving surgery decrease the risk of local recurrence. this study investigates the dosimetric aspects of intensity modulated radiotherapy (IMRT) compared to conventional tangential wedge-based beams techniques (CTT) of the whole breast in early stages breast cancer patients.   Materials and Methods: Co...

متن کامل

The evaluation of lung doses for radiation pneumonia risk in stereotactic body radiotherapy: A comparison of intensity modulated radiotherapy, intensity modulated arc therapy, cyberknife and helical tomotherapy

Background: Radiation Pneumonia (RP) is one of the most extensive side effects in Stereotactic Body Radiotherapy (SBRT) of lung cancer. SBRT are performed by means of Intensity Modulated Radiotherapy (IMRT), Intensity Modulated Arc Therapy (IMAT), CyberKnife (CK) or Helical Tomotherapy (HT) treatment methods. In this study, we performed a plan study to determine the plan parameter such as the M...

متن کامل

Dosimetric comparison of 3-dimensional conformal and intensity-modulated radiotherapy techniques for whole breast irradiation in the prone and supine positions

Background: The aim of this study was to compare the differences of the dosimetric parameters between three-dimensional conformal radiotherapy (3D-CRT) and simultaneous-integrated boost intensity-modulated radiotherapy (SIB-IMRT) techniques in the prone and supine positions for breast irradiation. Materials and Methods: Ten patients underwent a computed tomography simulation in both the prone a...

متن کامل

Dosimetric Comparison of 3D Tangential Radiotherapy of Post-Lumpectomy Breast at Two Different Energies

Introduction: Radiation therapy following breast conserving surgery is one of the most common procedures performed in any radiation oncology department. A tangential parallel-opposed pair is almost always the technique of choice for this purpose. This technique is often performed based on 3D treatment planning. The aim of this study was to compare 3D treatment planning for two different energie...

متن کامل

Early experience of tomotherapy-based intensity-modulated radiotherapy for breast cancer treatment.

AIMS New technology - specifically intensity-modulated radiotherapy (IMRT) - is now being applied to breast radiotherapy and a recent dosimetric analysis confirmed the advantages of IMRT over 'wedge-only' plans. Such application to everyday practice raises new issues and here we present the early experience of IMRT-based breast irradiation in a single centre. MATERIALS AND METHODS We present ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 58  شماره 

صفحات  -

تاریخ انتشار 2017