Direct qPCR quantification using the Quantifiler(®) Trio DNA quantification kit.

نویسنده

  • Jason Yingjie Liu
چکیده

The effectiveness of a direct quantification assay is essential to the adoption of the combined direct quantification/direct STR workflow. In this paper, the feasibility of using the Quantifiler(®) Trio DNA quantification kit for the direct quantification of forensic casework samples was investigated. Both low-level touch DNA samples and blood samples were collected on PE swabs and quantified directly. The increased sensitivity of the Quantifiler(®) Trio kit enabled the detection of less than 10pg of DNA in unprocessed touch samples and also minimizes the stochastic effect experienced by different targets in the same sample. The DNA quantity information obtained from a direct quantification assay using the Quantifiler(®) Trio kit can also be used to accurately estimate the optimal input DNA quantity for a direct STR amplification reaction. The correlation between the direct quantification results (Quantifiler(®) Trio kit) and the direct STR results (GlobalFiler™ PCR amplification kit(*)) for low-level touch DNA samples indicates that direct quantification using the Quantifiler(®) Trio DNA quantification kit is more reliable than the Quantifiler(®) Duo DNA quantification kit for predicting the STR results of unprocessed touch DNA samples containing less than 10pg of DNA.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Developmental validation of the quantifiler real-time PCR kits for the quantification of human nuclear DNA samples.

The Quantifiler Human DNA Quantification Kit and the Quantifiler Y Human Male DNA Quantification Kit were designed for the quantification of human genomic DNA in forensic samples. The kits use a real-time PCR-based process to quantify, respectively, total human DNA or human male DNA only. We report the results of a developmental validation study that we performed with the Quantifiler Kits, foll...

متن کامل

Developmental Validation of the QuantifilerTM Real-Time PCR Kits for the Quantification of Human Nuclear DNA Samples∗ ABSTRACT: The QuantifilerTM Human DNA Quantification Kit and the QuantifilerTM Y Human Male DNA Quantification

The QuantifilerTM Human DNA Quantification Kit and the QuantifilerTM Y Human Male DNA Quantification Kit were designed for the quantification of human genomic DNA in forensic samples. The kits use a real-time PCR-based process to quantify, respectively, total human DNA or human male DNA only. We report the results of a developmental validation study that we performed with the Quantifiler Kits, ...

متن کامل

Developmental validation of the Quantifiler Duo DNA Quantification kit for simultaneous quantification of total human and human male DNA and detection of PCR inhibitors in biological samples.

The Quantifiler Duo DNA Quantification kit enables simultaneous quantification of human DNA and human male DNA as well as detection of inhibitors of PCR in a single real-time PCR well. Pooled human male genomic DNA is used to generate standard curves for both human (ribonuclease P RNA component H1) and human male (sex determining region Y) specific targets. A shift in the cycle threshold (C(T))...

متن کامل

A duplex real-time qPCR assay for the quantification of human nuclear and mitochondrial DNA in forensic samples: implications for quantifying DNA in degraded samples.

A duplex real-time qPCR assay was developed for quantifying human nuclear and mitochondrial DNA in forensic samples. The nuclear portion of the assay utilized amplification of a approximately 170-190 bp target sequence that spans the repeat region of the TH01 STR locus, and the mitochondrial portion of the assay utilized amplification of a 69 bp target sequence in the ND1 region. Validation stu...

متن کامل

Analysis of multiple loci can increase reliability of detection of fetal Y-chromosome DNA in maternal plasma.

OBJECTIVE Aiming to develop more reliable methods for determination of fetal gender from maternal plasma we compared three different systems of polymerase chain reaction (PCR) detection of Y-chromosome DNA. METHODS Cell-free DNA was isolated from 96 samples of maternal plasma and (1) amplified using AmpFLSTR-Identifiler (15 autosomal STR loci and amelogenin) or AmpFLSTR-Yfiler (16 Y-chromosom...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Forensic science international. Genetics

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2014