Analysis of Stray Current Induced by Cathodic Protection on Steel- Framed Masonry Structures

نویسندگان

  • Y-Y. Wu
  • P. Lambert
چکیده

Cathodic protection (CP) has been successfully employed to protect steel-framed masonry buildings from corrosion related damage. When a CP system is installed to protect the structural members, other metallic items which are within the fabric of the structure but are not in direct electrical continuity may suffer from stray current interactions, resulting in accelerated corrosion of the discontinuous items. Therefore, these must be considered when CP systems are designed prior to installation. This paper presents both experimental and numerical studies into the risk and extent of stray current corrosion in steelframed masonry structures when subject to impressed current cathodic protection. The objective is to allow CP systems to be optimised so that interference is minimised without compromising the technical or cost benefits of this method of corrosion control.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Impressed Current on Bond Strength Between Steel Rebar and Concrete

The deterioration of bond strength between reinforcing steel and concrete as a result of impressed cathodic current with respect to the exposure time was investigated. A current in the magnitude of 3ma/ft2 (based on reinforcing rebar area) was used for a period of five years. Chemical analyses for sodium (Na+), potassium (K+) and chloride (Cl-) ions in concrete cylinders were performed as a fun...

متن کامل

Optimization of Cathodic Protection on Offshore Structures

Marine structures are one of the most important and susceptible facilities in Iran due to corrosion. The two methods of Cathodic Protection, namely, the cathodic protection with sacrificial anodes and cathodic protection using impressed current, are widely used for corrosion protection. According to the former, sacrificial anodes are installed at several points in the structure. Position of the...

متن کامل

Free vibration analysis of steel framed structures

This study based on free vibration analysis and study the behavior of framed structure under different frequency of vibration using ANSYS software and shaking table. A small scale uni-axial shaking table was prepared in laboratory, which can produce lower to moderate vibration, regarding frequency and velocity. Moment resisting framed structures constructed with connecting beam and column eleme...

متن کامل

Optimization of Cathodic Protection on Offshore Structures

Marine structures are one of the most important and susceptible facilities in Iran due to corrosion. The two methods of Cathodic Protection, namely, the cathodic protection with sacrificial anodes and cathodic protection using impressed current, are widely used for corrosion protection. According to the former, sacrificial anodes are installed at several points in the structure. Position of the...

متن کامل

APPLIED OF IMPRESSED CURRENT CATHODIC PROTECTION DESIGN FOR FUEL PIPELINE NETWORK AT NAVAL BASE

Indonesian Navy (TNI AL) is the main component for Maritime Security and Defence. Because of that, TNI AL needs Indonesian Warship (KRI) to covered Maritime area. The main requirement from KRI is fulfilled by demand. To pock of fuel demand from KRI at Naval Base, it needs a new pipeline of fuel distribution network system. The pipeline network system used for maximum lifetime must be protected ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011