Dead space and slope indices from the expiratory carbon dioxide tension-volume curve.
نویسندگان
چکیده
The slope of phase 3 and three noninvasively determined dead space estimates derived from the expiratory carbon dioxide tension (PCO2) versus volume curve, including the Bohr dead space (VD,Bohr), the Fowler dead space (VD,Fowler) and pre-interface expirate (PIE), were investigated in 28 healthy control subjects, 12 asthma and 29 emphysema patients (20 severely obstructed and nine moderately obstructed) with the aim to establish diagnostic value. Because breath volume and frequency are closely related to CO2 elimination, the recording procedures included varying breath volumes in all subjects during self-chosen/natural breathing frequency, and fixed frequencies of 10, 15 and 20 breaths x min(-1) with varying breath volumes only in the healthy controls. From the relationships of the variables with tidal volume (VT), the values at 1 L were estimated to compare the groups. The slopes of phase 3 and VD,Bohr at 1 L VT showed the most significant difference between controls and patients with asthma or emphysema, compared to the other two dead space estimates, and were related to the degree of airways obstruction. Discrimination between no-emphysema (asthma and controls) and emphysema patients was possible on the basis of a plot of intercept and slope of the relationship between VD,Bohr and VT. A combination of both the slope of phase 3 and VD,Bohr of a breath of 1 L was equally discriminating. The influence of fixed frequencies in the controls did not change the results. The conclusion is that Bohr dead space in relation to tidal volume seems to have diagnostic properties separating patients with asthma from patients with emphysema with the same degree of airways obstruction. Equally discriminating was a combination of both phase 3 and Bohr dead space of a breath of 1 L. The different pathophysiological mechanisms in asthma and emphysema leading to airways obstruction are probably responsible for these results.
منابع مشابه
Noninvasive measurement of mean alveolar carbon dioxide tension and Bohr's dead space during tidal breathing.
The lack of methodology for measuring the alveolar carbon dioxide tension (PA,CO2) has forced investigators to make several assumptions, such as that PA,CO2 is equal to end-tidal (PET,CO2) and arterial CO2 tension (Pa,CO2). The present study measured the mean PA,CO2 and Bohr's dead space ratio (Bohr's dead space/tidal volume (VD,Bohr/VT)) during tidal breathing. The method used is a new, simple...
متن کاملDoes phase 2 of the expiratory PCO2 versus volume curve have diagnostic value in emphysema patients?
It has been postulated that serial inhomogeneity of ventilation in the peripheral airways in emphysema is represented by the shape of expiratory carbon dioxide tension versus volume curve. We examined the diagnostic value of this test in patients with various degrees of emphysema. The volumes between 25-50% (V25-50) and 25-75% (V25-75) of the expiratory carbon dioxide tension versus volume curv...
متن کاملPhysiologically based indices of volumetric capnography in patients receiving mechanical ventilation.
Several indices of ventilatory heterogeneity can be identified from the expiratory CO2 partial pressure or CO2 elimination versus volume curves. The aims of this study were: 1) to analyse several computerizable indices of volumetric capnography in order to detect ventilatory disturbances; and 2) to establish the relationship between those indices and respiratory system mechanics in subjects wit...
متن کاملAspiration of dead space in the management of chronic obstructive pulmonary disease patients with respiratory failure.
INTRODUCTION Carbon dioxide clearance can be improved by reducing respiratory dead space or by increasing the clearance of carbon-dioxide-laden expiratory gas from the dead space. Aspiration of dead space (ASPIDS) improves carbon dioxide clearance by suctioning out (during expiration) the carbon-dioxide-rich expiratory gas while replacing the suctioned-out gas with oxygenated gas. We hypothesiz...
متن کاملSystematic errors and susceptibility to noise of four methods for calculating anatomical dead space from the CO2 expirogram.
BACKGROUND Anatomical dead space is usually measured using the Fowler equal area method. Alternative methods include the Hatch, Cumming, and Bowes methods, in which first, second, and third order polynomials, respectively, fitted to an expired CO2 volume vs expired volume curve, intercept the x-axis at the anatomical dead space. This study assessed systematic errors and susceptibility to noise ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The European respiratory journal
دوره 10 8 شماره
صفحات -
تاریخ انتشار 1997