A Common Source of Difficulty in High-resolution Radioautography

نویسنده

  • Lucien G. Caro
چکیده

In high-resolution radioautography, a common source of difficulty in the use of the loop method for applying Ilford L-4 emulsion (1) is an inhomogeneous distribution of water in the emulsion . This inhomogeneity may be due to bad environmental conditions during transportation. It is easily cured by melting the entire bottle of emulsion once before use. Our standard procedure for the preparation of electron microscope radioautigraphs, slightly modified from that described in reference 1, is now as follows : Specimen screens are attached by a small portion of their edge to a small piece of doublecoated masking tape (Scotch Brand No . 400) fixed to a microscope slide (Fig . 1) . When starting a fresh bottle of L-4 emulsion, the bottle is placed into a 45 °C bath. As soon as the content is completely liquified, it is mixed thoroughly and allowed to gel. 15 g of this emulsion is weighed, then melted at 45 °C in 15 ml of distilled water in a 250-ml beaker, with gentle stirring to avoid bubbles . The emulsion is placed in an ice bath for 1-5 min, then a bath at 20 °C (room temperature) . It should become quite viscous in about 10 min and remain in a state favorable for preparing films for an additional 10 min . A loop of copper wire (Fig. 2) is dipped in the emulsion and withdrawn slowly, forming a thin film in the loop . This film should gel almost imHEMOSTAT mediately. The loop is touched to the surface of the slide ; the gelled film falls on the grids and adheres to them very firmly. L-4 emulsion tends to vary slightly in its gelling properties, and the schedule of melting and cooling may have to be modified accordingly . If the film does not gel rapidly or if electron microscopic examination reveals gross uneveness in the distribution of silver halide crystals, the time of cooling in the ice bath should be increased slightly . When the viscosity of

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Resolution in Electron Microscope Radioautography

Experimental resolution values, half distances (HD), were determined for electron microscope radioautography with (14)C as the source of radioactivity. These were about a factor of 1.5-2 times higher than for tritium. Grain distributions normalized in units of HD were found to fit the "universal" curves previously obtained for tritium.

متن کامل

Investigation of the effect of source distance and scattering medium on spatial resolution and contrast of Gamma camera images [Persian]

By identifying the effect of any parameter such as distance, attenuation and scattering on the Line Spread Function (LSF), one can compensate the quantitative and qualitative destructive effect of such parameters by deconvolution method. Using a 99mTC line source, this study was performed on a single head ADAC SPECT system operating in planar mode. Variation of FWTM and FWHM and LSFs as a...

متن کامل

Robust Fuzzy Content Based Regularization Technique in Super Resolution Imaging

Super-resolution (SR) aims to overcome the ill-posed conditions of image acquisition. SR facilitates scene recognition from low-resolution image(s). Generally assumes that high and low resolution images share similar intrinsic geometries. Various approaches have tried to aggregate the informative details of multiple low-resolution images into a high-resolution one. In this paper, we present a n...

متن کامل

Detection of Microsatellite Instability by High-Resolution Melting Analysis in Colorectal Cancer

Background: Colorectal cancer (CRC) is the third most common cancer worldwide. microsatellite instability (MSI) is a molecular marker of a deficient mismatch repair system and happens in almost 15% of CRCs. Because of a wide frequency of MSI+ CRC in Iran compared to other parts of the world, the importance of screening for this type of cancer is highlighted. Methods: The most common MSI detecti...

متن کامل

The Use of 55fe in High-resolution Radioautography of Developing Red Cells

The radioisotope 59Fe is used extensively for biochemical investigations of hemoglobin synthesis in maturing red cells. Its usefulness for radioautography is more limited, largely because high-energy beta particles emitted by 5Fe exhibit a long path and, therefore, produce scattered patterns of reduced silver grains in photographic emulsion overlying labeled cells. Another isotope, however, low...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of Cell Biology

دوره 41  شماره 

صفحات  -

تاریخ انتشار 1969