The use of layer by layer self-assembled coatings of hyaluronic acid and cationized gelatin to improve the biocompatibility of poly(ethylene terephthalate) artificial ligaments for reconstruction of the anterior cruciate ligament.

نویسندگان

  • Hong Li
  • Chen Chen
  • Shurong Zhang
  • Jia Jiang
  • Hongyue Tao
  • Jialing Xu
  • Jianguo Sun
  • Wei Zhong
  • Shiyi Chen
چکیده

In this study layer by layer (LBL) self-assembled coatings of hyaluronic acid (HA) and cationized gelatin (CG) were used to modify polyethylene terephthalate (PET) artificial ligament grafts. Changes in the surface properties were characterized by scanning electron microscopy, attenuated total reflection Fourier transform infrared spectroscopy, energy-dispersive X-ray spectroscopy, and contact angle and biomechanical measurements. The cell compatibility of this HA-CG coating was investigated in vitro on PET films seeded with human foreskin dermal fibroblasts over 7days. The results of our in vitro studies demonstrated that the HA-CG coating significantly enhanced cell adhesion, facilitated cell growth, and suppressed the expression of inflammation-related genes relative to a pure PET graft. Furthermore, rabbit and porcine anterior cruciate ligament reconstruction models were used to evaluate the effect of this LBL coating in vivo. The animal experiment results proved that this LBL coating significantly inhibited inflammatory cell infiltration and promoted new ligament tissue regeneration among the graft fibers. In addition, the formation of type I collagen in the HA-CG coating group was much higher than in the control group. Based on these results we conclude that PET grafts coated with HA-CG have considerable potential as substitutes for ligament reconstruction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Does Intravenous or Intraarticular Tranexamic Acid (TXA) Reduce Joint Bleeding Following Arthroscopic Anterior Cruciate Ligament (ACL) Reconstruction and Arthroscopic Meniscectomy? Can Intraarticular Use be Harmful to Chondrocytes?

Arthroscopic knee surgery to perform partial meniscectomy and anterior cruciate ligament (ACL) reconstruction is frequent and effective, although a possible complication is postoperative intra-articular bleeding. When this complication occurs, in addition to the associated pain, the patient usually requires an arthrocentesis to avoid loss of joint mobility. Sometimes this problem ends up associ...

متن کامل

The Effect of Prehabilitation on the Self-Reported Outcomes of Anterior Cruciate Ligament Reconstruction: A Systematic Review Running Title:

Background and Purpose: Quadriceps weakness and disruption of proprioceptive function are common after anterior cruciate ligament (ACL) injury and consequently the surgery. Postoperative self-reported outcomes are affected by the preoperative defect. The purpose of this review study was to examine whether preoperative exercises can affect self-reported outcomes. Methods: The study started sear...

متن کامل

تحلیل دامنه حرکتی و سرعت زاویه ای مفاصل اندام تحتانی در بیماران دارای رباط صلیبی قدامی بازسازی شده هنگام فرود از ارتفاع

 Aims and background: Anterior cruciate ligament injury is the most common ligament injury of the lower limb that necessitates reconstruction as a proper treatment approach. It is now up to the researchers to ask, are the altered kinematic patterns in the lower limbs corrected by this reconstruction? The present study aims to analyze the range of motion and angular velocity of the lower limb jo...

متن کامل

The clinical Outcome of One-stage High Tibial Osteotomy and Anterior Cruciate Ligament Reconstruction. A Current Concept Systematic and Comprehensive Review

  Background: Patients with an anterior cruciate ligament-deficient varus-angulated knee may need not only an isolated high tibial osteotomy (HTO), but also an additional anterior cruciate ligament reconstruction (ACLR). A number of prospective clinical trials have been published considering the combination of HTO and ACL reconstruction. Our aim was to investigate whether one-stage combined HTO...

متن کامل

Investigation into the effect of UV/Ozone Irradiation on the dyeing ‎behaviour of Poly(lactic acid) and Poly(ethylene terephthalate) ‎Substrates

The effect of UV/Ozone irradiation together with the pretreatments using distilled water, hydrogen peroxide, and hydrogen peroxide/sodium silicate solutions on the dyeing depth of the poly(lactic acid), PLA, and poly(ethylene terephthalate), PET, fabrics by the application of disperse dyes were investigated and the results were compared with that of untreated fabrics. The results showed that th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta biomaterialia

دوره 8 11  شماره 

صفحات  -

تاریخ انتشار 2012