Experimental study of the roof thermal performance influence over the mean radiant interior temperature of an industrial building
نویسندگان
چکیده
Industrial building rehabilitation is one the latest trends within the field of sustainable development. However, these interventions often disregard the issue of user comfort, despite being the most important factor of energy efficiency. This work deals with the assessment of the indoor thermal conditions of a restored industrial building, considering not only air temperature but also mean radiant interior temperature. The research focuses in the influence of the radiative performance of the saw tooth roof of this building regarding these conditions. Results show that the analysed thermal parameters depend directly on the roof thermal behaviour. In fact, the glazed area of this type of roof is responsible for the 60% of the increase of the mean radiant temperature over air temperature. This result is a consequence of the high interior temperature reached by the glass panels, 47°C max, despite their northern orientation. These temperatures are a result of the diffuse radiation action and, particularly, the heat flux emitted by the opaque part of the saw tooth-roof, which significantly reduces the radiative cooling capacity of the glazed surface.
منابع مشابه
Study of thermal performance of building roofs in the city of Tehran
The design of a building can provide the highest thermal comfort in the interior without any mechanical equipment and save energy to a large extent. The roof of a building is an important part for thermal loss. This research studies the thermal performance of 14 conventional roof structures in Tehran city by using designbuilder 4.5. It is found that the polystyrene block performs best compared ...
متن کاملStudy on rooftop outdoor thermal environment and slab insulation performance of grass planted roof
The benefits of rooftop greening are ascertained in thermal perspective. It effectively reduces the near surface ambient temperature and the reflected irradiation from the rooftop slab, thus increasing the thermal comfort environment above the lawn and reduces the heat transferred through the rooftop slab. The former effect enables the potential usage of the rooftop spaces for human activity an...
متن کاملEnergy Conservation Potential of an Extensive Green Roof in Iran for One Year Duration
The temperature of cities continues to increase because of the heat island phenomenon and the undeniable climatic change. The observed high ambient temperatures intensify energy problems in cities, deteriorates comfort conditions, put in danger the vulnerable population and amplify the pollution problems. There are some suggested ways to reduce these issues, among them vegetated roofs are shown...
متن کاملVentilated hollow core slab as a thermal mass strategy and its effect on thermal comfort; (case study: lotion college, England)
Thermal mass is the material's ability to store heat and release it after an amount of time and concrete is considered one of the best thermal mass material. Since concrete has been used widely in many building constructions, by considering the capability of concrete in terms of thermal mass, it is worthwhile to use this ability of concrete in order to build buildings more healthy and comfortab...
متن کاملبهسازی حرارتی جدار ساختمانهای موجود در اقلیم سرد در ایران با بهرهگیری از ویژگیهای دیوار ترومب
This research is aimed to find an energy optimization method for existing buildings in cold climate regions of Iran. In the proposed system, a secondary skin is installed against the unglazed surfaces of the southern wall, creating a Trombe-wall. The sun-facing wall is then painted in black, and covered with a transparent material like clear glass, leaving a closed air gap between them. The res...
متن کامل