Performance enhancements of MCNP4B, MCNP5, and MCNPX for Monte Carlo Radiotherapy Planning Calculations in Lattice Geomet ries
نویسنده
چکیده
NATIONAL LABORATOR Y Los Alamos National Laborato ry, an affirmative action/equal opportunity employer, is operated by the University of California for the U .S . Depa rtment of Energy under contract W -7405-ENG-36 . By acceptance of this art icle, the publisher recognizes that the U .S. Government retains a nonexclusive, royalty-free license to publish or reproduce the published form of this contribution , or to allow others to do so , for U.S. Government purposes. Los Alamos National Laboratory requests that the publisher identify this article as work performed under the auspices of the U.S. Department of Energy . Los Alamos National Laborato ry strongly supports academic freedom and a researcher ' s right to publish ; as an institution , however, the Laboratory does not endorse the viewpoint of a publication or guarantee its technical correctness .
منابع مشابه
Dose Calculations for Lung Inhomogeneity in High-Energy Photon Beams and Small Beamlets: A Comparison between XiO and TiGRT Treatment Planning Systems and MCNPX Monte Carlo Code
Introduction Radiotherapy with small fields is used widely in newly developed techniques. Additionally, dose calculation accuracy of treatment planning systems in small fields plays a crucial role in treatment outcome. In the present study, dose calculation accuracy of two commercial treatment planning systems was evaluated against Monte Carlo method. Materials and Methods Siemens Once or linea...
متن کاملAssessment of Different Training Methods in an Artificial Neural Network to Calculate 2D Dose Distribution in Radiotherapy
Introduction: Treatment planning is the most important part of treatment. One of the important entries into treatment planning systems is the beam dose distribution data which maybe typically measured or calculated in a long time. This study aimed at shortening the time of dose calculations using artificial neural network (ANN) and finding the best method of training t...
متن کاملComparison of MCNP5 Dose Calculations inside the RANDO Phantom Irradiated with a MLC LinAc Photon Beam against Treatment Planning System PLUNC
MC treatment planning techniques provide a very accurate dose calculation compared to ‘conventional’ deterministic treatment planning systems. In the present work, PLanUNC (PLUNC), a set of software tools for radiotherapy treatment planning (RTP), is compared with MCNP5 (Monte Carlo N-Particle transport code) by calculating dose maps inside the RANDO phantom, utilized as the patient model, irra...
متن کاملPenumbra Measurements and Comparison of In-House and Standard Circular Cones by the Gafchoromic Film, Pinpoint Ion Chamber, and MCNPX Monte Carlo Simulation
Introduction: Penumbra is an important property of the radiation beam to obtain a suitable margin surrounding the target volume. Therefore, the precise penumbra width determination in stereotactic radiotherapy is necessary for treatment planning. This study aimed to compare the obtained results of penumbra width by in-house and standard circul...
متن کاملInvestigation of the dose enhancement effect due to gold nanoparticles at 18 MV radiotherapy using MAGIC-f and Monte Carlo methods Thoraco-Lumbar spinal cord fMRI in 3T Magnetic field
Introduction: Normoxic MAGIC-f polymer gels are established dosimeters used for three dimensional dos uantifications in radiotherapy. The high atomic number nanoparticles such as gold are nov adiosensitizers used to enhance doses delivered to tumors. The aim of this study was t vestigate the effect of gold nanoparticles (GNPs) in enhancing percentage depth doses (PDD ithin the...
متن کامل