Acute effects of nasal continuous positive airway pressure on 24-hour blood pressure and catecholamines in patients with obstructive sleep apnea.

نویسندگان

  • H Minemura
  • T Akashiba
  • H Yamamoto
  • T Akahoshi
  • N Kosaka
  • T Horie
چکیده

To assess the acute effects of nasal continuous positive airway pressure (CPAP) on the 24-hour blood pressure and the secretion of catecholamines in urine and plasma, we investigated the changes in the 24-hour blood pressure and urinary and plasma concentrations of epinephrine (E) and norepinephrine (NE) in 26 men with obstructive sleep apnea (OSA) with and without nasal CPAP. Nasal CPAP resulted in significant decreases in the daytime diastolic pressure (from 86 +/-16 mmHg to 83+/-12 mmHg), the nighttime diastolic pressure (from 81+/-12 mmHg to 77+/-9 mmHg) and the nighttime systolic pressures (from 125+/-15 mmHg to 120+/-10 mmHg). There was no significant difference between patients with and without CPAP in the daytime or nighttime urinary E level, but patients who received CPAP showed a significant decrease in daytime urinary NE level (from 156+/-112 microg/14h to 119+/-101 microg/14h) and nighttime urinary NE level (from 143+/-91 microg/10h to 112+/-65 microg/10h). The morning plasma level of NE also decreased (from 371+/-181 pg/ml to 273 +/-148 pg/ml) in patients who received nasal CPAP (p<0.02), but the plasma level of E remained unchanged. There were no correlations between PSG parameters and the reductions in blood pressure and the catecholamine levels induced by nasal CPAP. These findings suggest that OSA contributes, at least in part, to the development of systemic hypertension by increasing sympathetic nervous activity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Factors Affecting Patients’ Adherence to Continuous Positive Airway Pressure Therapy for Obstructive Sleep Apnea Disorder: A Multi-Method Approach

Background: Continuous positive airway pressure (CPAP) is the gold standard therapy for treating obstructive sleep apnea (OSA) disorder. However, patients’ adherence to its regular use is poor. The present study aimed to determine the adherence rate to CPAP therapy by identifying factors affecting its regular use and its associated problems and discomforts among a sample population in Mashhad (...

متن کامل

Frequent loss of nyctohemeral rhythm of intraocular pressure restored by nCPAP treatment in patients with severe apnea.

OBJECTIVE To assess 24-hour intraocular pressure (IOP) and ocular perfusion pressure rhythms in newly diagnosed apneic patients before and after nasal continuous positive airway pressure (nCPAP) treatment. METHODS Intraocular pressure (using a Tonopen XL) and ambulatory blood pressure, measured hourly for 24 hours, were analyzed in 18 consecutive patients with obstructive sleep apnea for nyct...

متن کامل

Effects of Biofeedback Therapy on Cardiovascular and Respiratory Indices in NREM Sleep Parasomnias with Obstructive Sleep Apnea: A Case study

Introduction: Non-REM parasomnias are a relatively common condition in the general human population. Current treatment plans are usually based on small case series and reports. Considering the effects of sleep disorders on different aspects of human life and the failure of pharmacological treatments in this field, the present study was designed to investigate a case of this sleep disorders with...

متن کامل

Effects of continuous positive airway pressure versus supplemental oxygen on 24-hour ambulatory blood pressure.

Obstructive sleep apnea (OSA) is associated with recurrent episodes of nocturnal hypoxia and increased risk for development of systemic hypertension. Prior studies have been limited, however, in their ability to show reduction in blood pressure after continuous positive airway pressure (CPAP) therapy, and the effect of supplemental oxygen alone on blood pressure in OSA has not been evaluated. W...

متن کامل

SLEEP DISORDERED BREATHING Nasal CPAP reduces systemic blood pressure in patients with obstructive sleep apnoea and mild sleepiness

Background: A randomised controlled study was undertaken to examine the effect of nasal continuous positive airway pressure (CPAP) on 24 hour systemic blood pressure (BP) in patients with obstructive sleep apnoea (OSA). Methods: Patients were fitted with an ambulatory BP measuring device as outpatients during normal activities and recorded for 24 hours before starting therapeutic or subtherapeu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Internal medicine

دوره 37 12  شماره 

صفحات  -

تاریخ انتشار 1998