Data scaling and temperature calibration in time-resolved photocrystallographic experiments.
نویسندگان
چکیده
Experiments in which structural changes in crystals are induced by pulsed-laser exposure involve an increase in sample temperature due to the dissipation of the deposited excess energy. The heat increase is especially pronounced when a large number of pulses is needed, as in pseudo-steady-state experiments conducted at conventional sources, but not negligible in synchrotron studies in which very short laser exposures may be adequate. The relative scaling of the light-ON and light-OFF data and the correction for temperature differences between the two sets are discussed.
منابع مشابه
Time-resolved X-ray diffraction of the photochromic alpha-styrylpyrylium trifluoromethanesulfonate crystal films reveals ultrafast structural switching.
The ultrafast structural dynamics of the [2+2] photocycloaddition of alpha-styrylpyrylium trifluoromethanesulfonate (TFMS) has been studied in great detail. During the photoreaction, optical and infrared spectroscopy confirms that crystals of alpha-styrylpyrylium change color. Since the reaction is reversible, it has been suggested to be used as an organic holographic storage device. The presen...
متن کاملTemperature dependence of continuum and time resolved photoluminescence of germanium nanostructures
Germanium nanostructures were generated in the post annealed germanium oxide thin films. Visible and near infrared photoluminescence bands were observed in the samples annealed at 350°C and 400°C, respectively. These different luminescence ranges are attributed to the presence of the defects in oxide matrix and quantum confinement effect in the germanium nanostructures, respectively. Decay ti...
متن کاملInstrumentation for photocrystallographic experiments of transient species.
Instrumentation for stroboscopic time-resolved diffraction studies at low temperatures is described. Exciting laser light is delivered to the crystal through an optical fiber. During the diffraction experiment, fluorescence from the sample is focused onto a fiber optic bundle surrounding the laser-light fiber, and monitored by a photodiode. A rotating slotted disk produces a pulsed X-ray beam w...
متن کاملOn Calibration of Modern Neural Networks
Confidence calibration – the problem of predicting probability estimates representative of the true correctness likelihood – is important for classification models in many applications. We discover that modern neural networks, unlike those from a decade ago, are poorly calibrated. Through extensive experiments, we observe that depth, width, weight decay, and Batch Normalization are important fa...
متن کاملSize Distribution Measurement of Candle\'s Soot Nanoparticles by Using Time Resolved Laser Induced Incandescence
Time resolved laser induced incandescence (LII) technique is used to measure size distribution of soot nanoparticles of candle's flame. Pulsed Nd:YAG laser is used to heat nanoparticles to incandescence temperature and the resulting signal is measured. Mass and energy balance equations are numerically solved to calculate temperature of soot particles in low fluence regime. Assuming Plank black ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Acta crystallographica. Section A, Foundations of crystallography
دوره 66 Pt 6 شماره
صفحات -
تاریخ انتشار 2010