OBJECTIVE The purposes of this study were to determine the following: 1) the exposure levels of municipal household waste (MHW) workers to diesel particulate matter (DPM) using elemental carbon (EC), organic carbon (OC), total carbon (TC), black carbon (BC), and fine particulate matter (PM 2.5) as indicators; 2) the correlations among the indicators; 3) the optimal indicator for DPM; and 4) factors that influence personal exposure to DPM. METHODS A total of 72 workers in five MHW collection companies were assessed over a period of 7 days from June to September 2014. Respirable EC/OC samples were quantified using the thermal optical transmittance method. BC and PM 2.5 were measured using real-time monitors, an aethalometer and a laser photometer. All results were statistically analyzed for occupational and environmental variables to identify the exposure determinants of DPM. RESULTS The geometric mean of EC, OC, TC, BC and PM 2.5 concentrations were 4.8, 39.6, 44.8, 9.1 and 62.0 μg/m3, respectively. EC concentrations were significantly correlated with the concentrations of OC, TC and BC, but not with those of PM 2.5. The exposures of the MHW collectors to EC, OC, and TC were higher than those of the drivers (p<0.05). Workers of trucks meeting Euro 3 emission standard had higher exposures to EC, OC, TC and PM 2.5 than those working on Euro 4 trucks (p<0.05). Multiple regression analysis revealed that the job task, European engine emission standard, and average driving speed were the most influential factors in determining worker exposure. CONCLUSIONS We assessed MHW workers' exposure to DPM using parallel sampling of five possible indicators. Of these five indicators, EC was shown to be the most useful indicator of DPM exposure for MHW workers, and the job task, European emission standard, and average driving speed were the main determinants of EC exposure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biodiesel versus diesel: a pilot study comparing exhaust exposures for employees at a rural municipal facility.

Many organizations interested in renewable, domestic energy have switched from petroleum diesel to biodiesel blends for use in transportation and heavy-duty equipment. Although considerable evidence exists on the negative health effects of petroleum diesel exhaust exposures in occupational settings, there has been little research examining biodiesel exposures. Working collaboratively with a loc...

متن کامل

Controlling and Monitoring Diesel Emissions in Underground Mines in the United States

The exposure of mine workers to diesel particulate matter (DPM) and gases is an issue of great concern to the underground mining community in the United States. Approximately 30,000 underground miners are potentially exposed to high concentrations of DPM. In January of 2001, the U.S. Mine Safety and Health Administration (MSHA) promulgated rules setting compliance standards for both underground...

متن کامل

Occupational exposure to particulate air pollution and mortality due to ischaemic heart disease and cerebrovascular disease.

OBJECTIVES A growing number of epidemiological studies are showing that ambient exposure to particulate matter air pollution is a risk factor for cardiovascular disease; however, whether occupational exposure increases this risk is not clear. The aim of the present study was to examine whether occupational exposure to particulate air pollution increases the risk for ischaemic heart disease and ...

متن کامل

Characteristics of particulate matter generated while handling municipal household waste.

OBJECTIVES This study was conducted to assess the size characteristics of particulate matter (PM) generated during waste collection and sorting, and to assess the effect of the type of waste-handling activity on levels of coarse and fine PM. METHODS A portable aerosol spectrometer calibrated to 1.2 //min was used to monitor PM generated during four types of waste-handling activities. The type...

متن کامل

Occupational exposure to particulate matter in 2 Portuguese waste-sorting units.

OBJECTIVES This study intended to characterize work environment contamination by particles in 2 waste-sorting plants. MATERIAL AND METHODS Particles were measured by portable direct-reading equipment. Besides mass concentration in different sizes, data related with the number of particles concentration were also obtained. RESULTS Both sorting units showed the same distribution concerning th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015