Clinical evaluation of short, machined-surface implants followed for 12 to 92 months.

نویسندگان

  • Georges Tawil
  • Roland Younan
چکیده

PURPOSE Bone resorption following tooth loss often limits the quantity of bone available for implant placement. The purpose of the present study was to evaluate the clinical outcome of 10-mm or shorter machined-surface implants when used exclusively in the treatment of various forms of edentulism. MATERIALS AND METHODS Two hundred sixty-nine screw-type Brånemark System implants (Nobel Biocare), 10 mm or shorter, were placed in 111 consecutively treated patients. Of the total, 88.8% were placed in the mandible and 11.2% were placed in the maxilla; 95.2% were used to treat partially edentulous situations, including single-tooth losses, of which 96.6% were in the premolar and molar regions. The patients were followed for periods of 12 to 92 months. RESULTS Of the 269 placed implants, 12 were lost. The overall survival rate was 95.5%. Bone quality 2 and 3 (Lekholm-Zarb classification of 1985) was found in 88.8% of the treated sites. There was no statistical difference in the survival rate of the 10-mm implants when compared to the shorter series (P > .05) or between the various implant diameters. The mean marginal bone loss was 0.71 +/- 0.65 mm. DISCUSSION The failure rate of 4.5% compares favorably with that of implants of different shape, surface characteristics, and length. Bone quality appeared to be the critical factor in implant survival, rather than bone quantity, in this patient series. CONCLUSIONS This study supports the survival of short, machined-surface implants when used for the treatment of partial edentulism in bone of good quality.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A prospective multicenter clinical trial of 3i machined-surface implants: results after 6 years of follow-up.

PURPOSE In this prospective multicenter clinical study, 1,179 3i standard threaded and self-tapping implants were followed for up to 6 years and monitored according to established success criteria. MATERIALS AND METHODS A total of 493 patients (240 men and 253 women) with a mean age of 45.1 years at implant surgery were enrolled at 6 research centers after being screened for exclusion criteri...

متن کامل

Influence of two different machined-collar heights on crestal bone loss.

PURPOSE The purpose of this trial was to evaluate crestal bone level changes radiographically in a standardized fashion over a period of 12 months in humans for implants with a 0.7-mm machined collar (implant type A) versus type B implants with a 1.5-mm machined collar. MATERIALS AND METHODS Twenty-five patients with multiple missing teeth in posterior sectors were randomly assigned to one of...

متن کامل

A quantitative comparison of machined commercially pure titanium and titanium-aluminum-vanadium implants in rabbit bone.

Screw-shaped implants made from rods of commercially pure titanium (grade 1) and titanium-aluminum-vanadium (grade 5) were machined, and the implant surface structures were numerically described before being placed in rabbit tibiae for healing periods of 1 months, 6 months, and 12 months. Quantitative comparisons of the removal torque (Ncm) necessary to loosen the implants from the bone bed wer...

متن کامل

Anchorage of machined and TPS-coated dental implants of various lengths: An in vivo study in the dog maxilla

Background and objectives. The use of short implants is nowadays frequent in daily practice. The objective of this experimental study was to test the correlation between extremely different implant surfaces and the anchorage of short implants. Materials and Methods. The anchorage of machined-surface and titanium-plasma sprayed (TPS) implants of various lengths was investigated in the dog maxill...

متن کامل

The immediately loaded single implant-retained mandibular overdenture: a 36-month prospective study.

PURPOSE The aim of this study was to ascertain whether simplifying mandibular overdenture treatment by using single-stage surgery and immediate prosthetic loading of a single implant will achieve acceptable implant success rates, functional improvement, and increased patient satisfaction. As part of this study, the Mk III Branemark implant with an oxidized surface was compared to the classic ma...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The International journal of oral & maxillofacial implants

دوره 18 6  شماره 

صفحات  -

تاریخ انتشار 2003