A novel technique for intra-aortic balloon positioning in the intensive care unit.

نویسنده

  • Vijish Venugopal
چکیده

Proper positioning of the intra-aortic balloon catheter is very important as an improperly placed balloon can cause problems. A balloon placed too high can block off the arch vessels, whereas one placed too low can block the renal and splanchnic vessels. We propose a simple and reliable technique to properly position the intra-aortic balloon pump (IABP) catheter without the use of any sophisticated or expensive equipment in the intensive care unit if the catheter has migrated from the previously placed desired position. In this technique, we rely on the left radial arterial trace obliteration as the IABP catheter is pushed in along a guidewire as a marker for tip positioning.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Predictive Factors for Delayed Extubation in the Intensive Care Unit after Coronary Artery Bypass Grafting; A Southern Iranian Experience

Background: Early extubation is implemented in cardiothoracic units worldwide for its advantages such as decreased mortality, morbidity, and hospitalization costs. We conducted a retrospective study to evaluate potential factors which may affect extubation time. Methods: The records of 334 eligible patients who underwent elective coronary artery bypass grafting (CABG) in 2008 in Kowsar ...

متن کامل

Evaluation of Factors Influencing Liver Function Test in On-Pump Coronary Artery Bypass Graft Surgery

Background: Liver dysfunction during on-pump coronary artery bypass graft surgery (CABG) is a rare complication but is associated with significant morbidity and mortality. The ability to identify high-risk patients may be helpful in planning appropriate management strategies. We aimed to evaluate the factors influencing liver function tests during on-pump CABG.Methods: In 146 patients scheduled...

متن کامل

The Evaluation of Survival in Patients Who Need Intra Aortic Balloon Pump (IABP) after Cardiac Surgery

Introduction: Insome cases, assist devices are required to ensure an adequate cardiac output after cardiac surgery. Intra-aortic balloon pump (IABP) is the most commonly used cardiac assist device, which provides first-line support for patients with heart failure. The aim of this study was to determine factors affecting the mortality rate of patients receiving IABP. Materials & Methods:  In thi...

متن کامل

Intra-aortic balloon pumping: does posture matter?

BACKGROUND The effect of the posture of semirecumbent patients on the hemodynamics and performance of intra-aortic balloon (IAB) were studied in vivo and in vitro. METHODS An IAB was inserted into a glass tube filled with saline, fully inflated and deflated using an intra-aortic balloon pump (IABP). Three successive cycles were filmed at 125 frames/s with the tube positioned at various angles...

متن کامل

Fatal aluminium phosphide poisoning due to myocardial depression refractory to high dose inotropic support and intra-aortic balloon counterpulsation

We report a case of aluminium phosphide poisoning that presented to us with refractory myocardial depression. This patient developed worsening circulatory failure that did not respond to inotropic or vasopressor support and intra-aortic balloon counterpulsation. She went on to develop progressive metabolic acidosis, renal failure and died within 48 hours of admission to the intensive care unit.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of extra-corporeal technology

دوره 44 3  شماره 

صفحات  -

تاریخ انتشار 2012