Jaw thrust as a predictor of insertion conditions for the proseal laryngeal mask airway.

نویسندگان

  • Russell Townsend
  • Joseph Brimacombe
  • Christian Keller
  • Volker Wenzel
  • Holger Herff
چکیده

We test the hypothesis that the response to jaw thrust is an effective predictor of insertion conditions for the ProSeal laryngeal mask airway (ProSeal LMA). One hundred and sixty patients (ASA grade 1-3, aged >18 yr) were studied. Five anesthetists blinded to the response to jaw thrust participated in the study, each performed >30 insertions. Induction of anesthesia was with propofol titrated to loss of lash reflex and apnea. A standard amount of jaw thrust was applied and any motor response noted by three observers. The ProSeal LMA was inserted using the standard digital technique. Insertion conditions were considered optimal if there was no motor or upper airway reflex response to insertion. There was no response to jaw thrust in 86% (137/160) of patients and insertion was optimal in 76% (121/160) of patients. A response to jaw thrust predicted suboptimal insertion conditions in 74% (17/23) and a lack of response predicted optimal insertion conditions in 84% (115/137). The accuracy, sensitivity and specificity were 0.82, 0.95 and 0.44, respectively. We conclude thatjaw thrust is a reliable predictor of insertion conditions for the ProSeal LMA with the digital insertion technique after induction of anesthesia with propofol. We suggest that clinicians learn how to apply the correct amount of jaw thrust and perform this test routinely.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

COMPARISON BETWEEN THE EFFICACY OF TRAPEZIUS SQUEEZING TEST AND JAW THRUST MANEUVER FOR PREDICTION OF SUCCESSFUL INSERTION OF LARYNGEAL MASK AIRWAY

Background & Aims: The aim of this study was to compare trapezius squeezing and jaw thrust to evaluate suitable conditions for laryngeal mask airway (LMA) insertion. Materials & Methods: In this clinical trial study, 138 patients with ASA physical status 1 or 2 who were candidates for elective surgery of shin fracture were randomly assigned into one of the groups of trapezius squeeze and raisi...

متن کامل

Randomized crossover comparison of the proseal with the classic laryngeal mask airway in unparalysed anaesthetized patients.

BACKGROUND The ProSeal is a wire-reinforced laryngeal mask airway with an additional drain tube that leads to the distal tip of the laryngeal cuff. The design should improve the seal with the larynx. METHODS The ProSeal and classic laryngeal mask airways were compared in 180 patients in a randomized crossover study. Patients were anaesthetized without neuromuscular blocking drugs. RESULTS T...

متن کامل

Comparison of the trapezius squeezing test and jaw thrust as indicators for laryngeal mask airway insertion in adults

BACKGROUND The purpose of this study was to compare the effectiveness of the trapezius squeezing test with that of the jaw thrust maneuver as clinical indicators of adequate conditions for laryngeal mask airway (LMA) insertion in adults under sevoflurane anesthesia. METHODS One hundred adult patients of ASA physical status 1 or 2 undergoing minor surgical procedures were randomly allocated to...

متن کامل

The ProSeal laryngeal mask airway is an effective alternative to laryngoscope-guided tracheal intubation for gynaecological laparoscopy.

We tested the hypothesis that the ProSeal laryngeal mask airway is superior to laryngoscope-guided tracheal intubation for gynaecological laparoscopy. One-hundred and eighty consecutive patients (ASA grade 1-2, aged 18-80 y) were divided into two equal-sized groups for airway management with the ProSeal laryngeal mask airway or tracheal tube. Induction was with fentanyl/propofol, maintenance wi...

متن کامل

Comparison of the Laryngeal Mask Airways: Laryngeal Mask Airway-classic and Laryngeal Mask Airway-proseal in Children

Introduction In the past 25 years with the development of various supraglottic airway devices, the armamentarium for airway management has increased. In our study, the laryngeal mask airway (LMA)-ProSeal is compared with the LMA-Classic with respect to as follows: (a) Ease of insertion and number of insertion attempts, (b) Device positional stability and possible oropharyngeal leak, (c) Airway ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Middle East journal of anaesthesiology

دوره 20 1  شماره 

صفحات  -

تاریخ انتشار 2009