Application of semiconductor strain gauge for continuous measurement of intracranial pressure.

نویسندگان

  • H Nagai
  • A Ikeyama
  • S Maeda
  • T Chiku
  • I Igarashi
چکیده

In order to record intracranial pressure continuously, we have recently developed a microminiature pressure transducer using semiconductor strain gauges. The pressure cell has a small disk-shaped structure, and it can be directly inserted into the intracranial cavity through a small burr hole. Previous investigations of the semiconductor strain gauge have dealt almost exclusively with the field of technology. In 1954, the first piezoresistive measurements for semiconductors were made in connection with a basic research for the transistor technology. Shortly after the original measurements, efforts were made toward applications. One of us, Igarashi, studied the piezoresistive semiconductor strain gauges of Germanium and Silicon in 1956 6l 7J , and devised a miniature pressure cell in 1965 for the purpose of measuring the pressure in the technological field 1l . The semicondutctor strain gauge is generally small in size. Although it has about 70 times higher sensitive gauge factor than that of the wire strain gauge, the former is affected by temperature about 10 times more than that of the latter. It might be, therefore, adopted into the living body as a device for measuring intracranial pressure, if only the compensation for temperature effects is ascertained. In this paper , a newly devised microminiature pressure cell is introduced and its clinical as well as experimental use is demonstrated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Residual Stresses Measurement of a Quenched Cylinder using Slitting Method

Residual Stress measurement has gained interests among researchers for many years due to its great influence on the structural integrity. Slitting method is one of the destructive techniques that relies on the introduction of an increasing cut to a part containing residual stresses. Similar to all other mechanical strain relief techniques, slitting also suffers from its shortcomings during the ...

متن کامل

Design of Continuous Gauge Near-Bit Stabilizer, Using Optimized Hydraulics and Gauge Geometry in Mishan andAghajari Formation

The main task of drilling the formation by the bit is done via scraping, crushing and grinding. Discharging the fluid from the bit nozzles is done with high pressure which assists to break the rocks. Different parameters affect the bit selection and design for each drilling formation, but the most important one is drillability that depends on hardness of the formation. In this paper, the design...

متن کامل

The Effect of Gauge Measurement Capability and Dependency Measure of Process Variables on the MCp

It has been proved that process capability indices provide very efficient measures of the capability of processes from many different perspectives. These indices have been widely used in the manufacturing industry for measuring process reproduction capability according to manufacturing specifications. In the past few years, univariate capability indices have been introduced and used to characte...

متن کامل

Experimental evaluation of the Spiegelberg intracranial pressure and intracranial compliance monitor. Technical note.

The goal of this study was to compare the Spiegelberg intraventricular intracranial pressure (ICP)/intracranial compliance monitoring device, which features an air-pouch balloon catheter, with existing gold-standard methods of measuring ICP and intracranial compliance. A Spiegelberg intraventricular catheter, a standard intraventricular catheter, and a Codman intraparenchymal ICP microsensor we...

متن کامل

Investigation of Important Parameters in Residual Stress Determination in Isotropic Plates and Laminated Composites by Slitting Method

In the slitting method, a small width slit is created incrementally through the thickness of the stressed specimen and the released strains in each increment are recorded by a strain gauge. Compliance coefficients relate the measured strains to the residual stresses. This paper investigates the important parameters influencing the calculation of compliance coefficients for isotropic plates and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nagoya journal of medical science

دوره 33 3  شماره 

صفحات  -

تاریخ انتشار 1971