An adaptive transfer function for deriving the aortic pressure waveform from a peripheral artery pressure waveform.

نویسندگان

  • Gokul Swamy
  • Da Xu
  • N Bari Olivier
  • Ramakrishna Mukkamala
چکیده

We developed a new technique to mathematically transform a peripheral artery pressure (PAP) waveform distorted by wave reflections into the physiologically more relevant aortic pressure (AP) waveform. First, a transfer function relating PAP to AP is defined in terms of the unknown parameters of a parallel tube model of pressure and flow in the arterial tree. The parameters are then estimated from the measured PAP waveform along with a one-time measurement of the wave propagation delay time between the aorta and peripheral artery measurement site (which may be accomplished noninvasively) by exploiting preknowledge of aortic flow. Finally, the transfer function with its estimated parameters is applied to the measured waveform so as to derive the AP waveform. Thus, in contrast to the conventional generalized transfer function, the transfer function is able to adapt to the intersubject and temporal variability of the arterial tree. To demonstrate the feasibility of this adaptive transfer function technique, we performed experiments in 6 healthy dogs in which PAP and reference AP waveforms were simultaneously recorded during 12 different hemodynamic interventions. The AP waveforms derived by the technique showed agreement with the measured AP waveforms (overall total waveform, systolic pressure, and pulse pressure root mean square errors of 3.7, 4.3, and 3.4 mmHg, respectively) statistically superior to the unprocessed PAP waveforms (corresponding errors of 8.6, 17.1, and 20.3 mmHg) and the AP waveforms derived by two previously proposed transfer functions developed with a subset of the same canine data (corresponding errors of, on average, 5.0, 6.3, and 6.7 mmHg).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Blind identification of the aortic pressure waveform from multiple peripheral artery pressure waveforms.

We have developed a new technique to estimate the clinically relevant aortic pressure waveform from multiple, less invasively measured peripheral artery pressure waveforms. The technique is based on multichannel blind system identification in which two or more measured outputs (peripheral artery pressure waveforms) of a single-input, multi-output system (arterial tree) are mathematically analyz...

متن کامل

Validation of the transfer function technique for generating central from peripheral upper limb pressure waveform.

Central aortic pressure waveforms can be calculated from the radial artery pressure waveform using a generalized transfer function to correct for pressure wave distortion in the upper limb. Although validated to standards conventionally applied, reservations are still expressed on use of this process, because of the relatively small number of patients from whom appropriate invasive data were ob...

متن کامل

Pressure wave reflection assessed from the peripheral pulse: is a transfer function necessary?

Synthesis of the aortic pressure waveform by application of a transfer function to the radial pulse allows the estimation of aortic systolic blood pressure and aortic augmentation index, an index of pressure wave reflection derived from the early systolic component of the waveform. The accuracy of this approach for determining the aortic augmentation index has been questioned, however, and it m...

متن کامل

A Lumped Parameter Method to Calculate the Effect of Internal Carotid Artery Occlusion on Anterior Cerebral Artery Pressure Waveform

Background and Objective: Numerical modeling of biological structures would be very helpful tool to analyze hundreds of human body phenomena and also diseases diagnosis. One physiologic phenomenon is blood circulatory system and heart hemodynamic performance that can be simulated by utilizing lumped method. In this study, we can predict hemodynamic behavior of one artery of circulatory system (...

متن کامل

Can a clinically useful aortic pressure wave be derived from a radial pressure wave?

BACKGROUND The information contained in arterial pressure waveforms is probably underused by most clinicians who manage critically ill patients. It is not generally known that an aortic pressure wave can be synthesized by applying a generalized transfer function to the radial arterial pressure wave. We validated a commercially available system, SphygmoCo (PWV Medical, Sydney). METHODS Ascendi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of physiology. Heart and circulatory physiology

دوره 297 5  شماره 

صفحات  -

تاریخ انتشار 2009