4D Model Reconstruction of Patient-Specific Cardiac Mesh from Segmented Contour Lines
نویسندگان
چکیده
We propose an automatic algorithm for the reconstruction of a set of patient-specific dynamic cardiac mesh model with 1-to-1 mesh correspondence over the whole cardiac cycle. This work focus on both the reconstruction technique of the initial 3D model of the heart and also the consistent mapping of the vertex positions throughout all the 3D meshes. This process is technically more challenging due to the wide interval spacing between MRI images as compared to CT images, making overlapping blood vessels much harder to discern. We propose a tree-based connectivity data structure to perform a filtering process to eliminate weak connections between contours on adjacent slices. The reconstructed 3D model from the first time step is used as a base template model, and deformed to fit the segmented contours in the next time step. Our algorithm has been tested on an actual acquisition of cardiac MRI images over one cardiac cycle.
منابع مشابه
Automatic 4D Reconstruction of Patient-Specific Cardiac Mesh with 1-to-1 Vertex Correspondence from Segmented Contours Lines
We propose an automatic algorithm for the reconstruction of patient-specific cardiac mesh models with 1-to-1 vertex correspondence. In this framework, a series of 3D meshes depicting the endocardial surface of the heart at each time step is constructed, based on a set of border delineated magnetic resonance imaging (MRI) data of the whole cardiac cycle. The key contribution in this work involve...
متن کاملFrom 4D Medical Images (CT, MRI, and Ultrasound) to 4D Structured Mesh Models of the Left Ventricular Endocardium for Patient-Specific Simulations
With cardiovascular disease (CVD) remaining the primary cause of death worldwide, early detection of CVDs becomes essential. The intracardiac flow is an important component of ventricular function, motion kinetics, wash-out of ventricular chambers, and ventricular energetics. Coupling between Computational Fluid Dynamics (CFD) simulations and medical images can play a fundamental role in terms ...
متن کاملPreformed vs intraoperative bending of titanium mesh for orbital reconstruction.
OBJECTIVE The most accurate orbital reconstructions result from an anatomic repair of the premorbid orbital architecture. Many different techniques and materials have been used; unfortunately, there is currently no optimal method. This study compares the use of preformed vs intraoperative bending of titanium mesh for orbital reconstruction in 2-wall orbital fractures. STUDY DESIGN Cadaver-bas...
متن کاملDynamic Surface Reconstruction from 4D-MR Images
In this work we present a new analysis technique for dynamic 3D images. The method allows the reconstruction of dynamic surfaces describing object boundaries in the 3D images over time. The only input of the user is a grey value threshold used for boundary detection and a bounding box around the surfaces of the object of interest. The output of our method is a dynamic surface mesh that tracks t...
متن کاملA Simulation Study on Patient Setup Errors in External Beam Radiotherapy Using an Anthropomorphic 4D Phantom
Introduction Patient set-up optimization is required in radiotherapy to fill the accuracy gap between personalized treatment planning and uncertainties in the irradiation set-up. In this study, we aimed to develop a new method based on neural network to estimate patient geometrical setup using 4-dimensional (4D) XCAT anthropomorphic phantom. Materials and Methods To access 4D modeling of motion...
متن کامل