Ultrasound tightening of facial and neck skin: a rater-blinded prospective cohort study.

نویسندگان

  • Murad Alam
  • Lucile E White
  • Nicolle Martin
  • Joslyn Witherspoon
  • Simon Yoo
  • Dennis P West
چکیده

BACKGROUND Nonablative skin tightening technologies offer the prospect of reduction of wrinkles and skin sagging with minimal downtime, discomfort, and risk of adverse events. The excellent safety profile is mitigated by the limited efficacy of such procedures. OBJECTIVE We sought to assess the efficacy of ultrasound skin tightening for brow-lift in the context of a procedure treating the full face and neck. METHODS This was a rater-blinded, prospective cohort study at a dermatology clinic in an urban academic medical center. Subjects were medicated with topical anesthetic and then treated with an investigational focused intense ultrasound tightening device to the forehead, temples, cheeks, submental region, and side of neck using the following probes: 4 MHz, 4.5-mm focal depth; 7 MHz, 4.5-mm focal depth; and 7 MHz, 3.0-mm focal depth. Standardized photographs of front and side views were obtained at 2, 7, 28, 60, and 90 days; rating scales of pain, adverse events, physical findings, and patient satisfaction were also completed. Primary outcome measure was detection of improvement in paired comparison of pretreatment and posttreatment (day 90) photographs by 3 masked expert physician assessors, cosmetic and laser dermatologists, and plastic surgeons who were not authors. Second primary outcome measure was objective brow elevation as quantitated by a standard procedure using fixed landmarks. Secondary outcomes measure was patient satisfaction as measured by a questionnaire. RESULTS A total of 36 subjects (34 female) were enrolled, one subject dropped out, and 35 subjects were evaluated. Median age was 44 years (range 32-62). On the first primary outcome measure, 30 of 35 subjects (86%) were judged by the 3 masked experienced clinician raters to show clinically significant brow-lift 90 days after treatment (P = .00001). On the second primary outcome measure, mean value of average change in eyebrow height as assessed by measurement of photographs at 90 days was 1.7 mm. LIMITATIONS Limitations of this study include the inability to quantitatively measure lower face tightening because of the lack of fixed anatomic landmarks in this area. CONCLUSION Ultrasound appears to be a safe and effective modality for facial skin tightening. A single ultrasound treatment of the forehead produced on average brow height elevation of slightly less than 2 mm. Most treated individuals responded, commonly with accompanying transitory mild erythema and edema.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intense focused ultrasound tightening in Asian skin: clinical and pathologic results.

BACKGROUND Laxity and wrinkles of the aging face are common cosmetic concerns. Intense focused ultrasound (IFUS), a novel treatment modality for skin laxity, produces thermal effects at various depths while sparing overlying epidermis. OBJECTIVE To evaluate the safety and efficacy of IFUS in facial skin tightening. METHODS AND MATERIALS Twenty-two Korean patients with facial laxity were ana...

متن کامل

Multiple pass ultrasound tightening of skin laxity of the lower face and neck.

BACKGROUND Skin laxity is a common complaint of patients who request skin rejuvenation. Radiofrequency and infrared light are widely used for nonablative treatment of skin laxity. Intense focused ultrasound (IFUS) has been investigated as a tool for the treatment of solid benign and malignant tumors for many decades but is only now beginning to emerge as a potential noninvasive alternative to c...

متن کامل

Noninvasive skin tightening: focus on new ultrasound techniques

Microfocused ultrasound (MFU) has been recently developed to meet the ever-growing public demand for achieving significant, noninvasive skin lifting and tightening. MFU can be focused on subcutaneous tissue where the temperature briefly reaches greater than 60°C, producing small (<1 mm(3)) thermal coagulation points to a depth of up to 5 mm within the mid-to-deep reticular layer of the dermis a...

متن کامل

High-Intensity Focused Ultrasound for the Treatment of Wrinkles and Skin Laxity in Seven Different Facial Areas.

BACKGROUND High-intensity focused ultrasound (HIFU) treatment has recently emerged in response to the increasing demand for noninvasive procedures for skin lifting and tightening. OBJECTIVE This study was aimed at evaluating the clinical efficacy of and patient satisfaction with HIFU treatment for wrinkles and laxity in seven different areas of the face in Asian skin. METHODS Twenty Korean ...

متن کامل

Skin tightening technologies.

Radiofrequency (RF) and intense focused ultrasound (IFUS) are increasingly used to address skin laxity of the face and neck. Both nonablative RF and ultrasound create a heat-induced tissue response that leads to collagen remodeling and other ultrastructural changes. Although these treatments are not meant to replace surgical procedures, patient satisfaction in the majority of studies has been c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American Academy of Dermatology

دوره 62 2  شماره 

صفحات  -

تاریخ انتشار 2010