Noninvasive positive-pressure ventilation in clinical practice at a large university-affiliated Brazilian hospital
نویسندگان
چکیده
OBJECTIVES To describe noninvasive positive-pressure ventilation use in intensive care unit clinical practice, factors associated with NPPV failure and the associated prognosis. METHODS A prospective cohort study. RESULTS Medical disorders (59%) and elective surgery (21%) were the main causes for admission to the intensive care unit. The main indications for the initiation of noninvasive positive-pressure ventilation were the following: post-extubation, acute respiratory failure and use as an adjunctive technique to chest physiotherapy. The noninvasive positive-pressure ventilation failure group was older and had a higher Simplified Acute Physiology Score II score. The noninvasive positive-pressure ventilation failure rate was 35%. The main reasons for intubation were acute respiratory failure (55%) and a decreased level of consciousness (20%). The noninvasive positive-pressure ventilation failure group presented a shorter period of noninvasive positive-pressure ventilation use than the successful group [three (2-5) versus four (3-7) days]; they had lower levels of pH, HCO3 and base excess, and the FiO2 level was higher. These patients also presented lower PaO2:FiO2 ratios; on the last day of support, the inspiratory positive airway pressure and expiratory positive airway pressure were higher. The failure group also had a longer average duration of stay in the intensive care unit [17 (10-26) days vs. 8 (5-14) days], as well as a higher mortality rate (9 vs. 51%). There was an association between failure and mortality, which had an odds ratio (95% CI) of 10.6 (5.93 -19.07). The multiple logistic regression analysis using noninvasive positive pressure ventilation failure as a dependent variable found that treatment tended to fail in patients with a Simplified Acute Physiology Score II ≥ 34, an inspiratory positive airway pressure level ≥ 15 cmH2O and pH<7.40. CONCLUSION The indications for noninvasive positive-pressure ventilation were quite varied. The failure group had a longer intensive care unit stay and higher mortality. Simplified Acute Physiology Score II ≥ 34, pH<7.40 and higher inspiratory positive airway pressure levels were associated with failure.
منابع مشابه
New modalities for non-invasive positive pressure ventilation: A review article
Efficiency of non-invasive positive pressure ventilation in the treatment of respiratory failure has been shown in many published studies. In this review article, we introduced new modalities of non-invasive ventilation (NIV), clinical settings in which NIV can be used and a practical summary of the latest official guidelines published by the European Respiratory Clinical Practice. Clinical tri...
متن کاملA Comparison between Nasal Intermittent Positive Pressure Ventilation and Nasal Continuous Positive Airway Pressure Ventilation in the Treatment of Neonatal Respiratory Distress Syndrome
Background: Nasal intermittent positive pressure ventilation (NIPPV) is a non-invasive ventilatory mode, which delivers mechanical ventilation via nasal tubes or prongs. The present study was conducted to compare the efficacy of NIPPV and nasal continuous positive airway pressure ventilation (NCPAP) in reducing the need for intubation in preterm infants with respiratory distress syndrome (RDS)....
متن کاملEffectiveness assessment of a guideline based protocol for ventilatory support management of COPD exacerbations in an emergency department
OBJECTIVES To investigate clinical outcomes according to ventilatory support indication in subjects with chronic obstructive pulmonary disease exacerbation in a "real-life" Emergency Department and to analyze potential predictors of successful noninvasive positive pressure ventilation. METHODS Retrospective cohort performed over an 18-month period, comparing the following patient groups with ...
متن کاملEfficiency and outcome of non-invasive versus invasive positive pressure ventilation therapy in respiratory failure due to chronic obstructive pulmonary disease
Background: Application noninvasive ventilation in the patients with exacerbation of chronic obstructive pulmonary disease (COPD) reduced mortality. This case-control study was designed to compare efficiency and outcome of non-invasive (NIV) versus invasive positive pressure ventilation (IPPV) in respiratory failure due to COPD Methods: The patients were assigned to NIV or IPPV intermittantl...
متن کاملThe use of noninvasive positive pressure ventilation in the emergency department: results of a randomized clinical trial.
OBJECTIVE To determine whether the use of noninvasive positive pressure ventilation (NPPV) in the emergency department (ED) will reduce the need for tracheal intubation and mechanical ventilation. DESIGN Randomized, controlled, prospective clinical trial. SETTING ED of Barnes-Jewish Hospital, a university-affiliated teaching hospital. PATIENTS Twenty-seven patients meeting a predetermined...