Volatility of radiopharmacy-prepared sodium iodide-131 capsules.

نویسندگان

  • J M Bright
  • T T Rees
  • L E Baca
  • R L Green
چکیده

OBJECTIVE The aims of this study were to quantify the extent of volatilization from 131I-NaI therapeutic capsules prepared in a centralized radiopharmacy and to quantify the amount of volatile 131I released from a dispensing vial containing a compounded 131I-NaI therapy capsule. METHODS Therapy capsules were prepared by injecting 131I oral solution into capsules containing anhydrous dibasic sodium phosphate. Volatilized activity was obtained by filtering air drawn across samples that were placed open on the bottom of a sample holder cup. Volatile 131I was captured by filtering it through 3 triethylenediamine-impregnated carbon cartridge filters, arranged in series. To quantify the amount of volatile 131I released from a dispensing vial during a simulated patient administration, a vial containing a compounded 131I therapy capsule was opened inside a collapsible plastic bag and all the air was drawn across TEDA-impregnated carbon cartridge filters. RESULTS The 370-MBq (10-mCi) 131I capsules from the first part of the experiment released an average of 0.035% (SD 0.031%) of the capsule activity on the first day, 0.012% (SD 0.002%) on the second day, and 0.012% (SD < 0.001%) for days 3 through 5. The 37-MBq (1-mCi) 131I capsules released an average of 0.058% (SD 0.025%) on the first day, 0.029% (SD 0.009%) on the second day, and 0.020% (SD 0.004%) on the third day. The activity released from the vial during a simulated patient administration was 0.00093% of the 131I capsule activity. CONCLUSION The amount of 131I, which volatilized daily from the exposed therapy capsules, was a small percentage of the capsule activity. The volatile 131I that would be released during a patient administration was much less than the activity that volatilized from the exposed therapy capsules.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of radiation dose rates and urinary activity of patients received Sodium Iodide-131 for treatment of differentiated thyroid carcinoma [Persian]

Sodium Iodide-131 is administrated for treatment of hyperthyroidism and thyroid cancer. Iodine-131 has multiple routs of excretion (Urine, saliva, sweat, milk, feces, exhalation) from the body. Patients receiving Sodium Iodide-131 therapy exposes other persons and the environment to unwanted radiation and contamination. The major source of radiation dose from administration of Iodine-131 ...

متن کامل

Structural Behavior of Tc and I ions in Nuclear Waste Glass

Technetium-99 (Tc) and iodine-129 (I) are two long-lived fission products of high volatility, which makes their study in glass structure challenging. Both technetium and iodine have broad ranging multivalent chemistry and complex reactivity dependent on redox conditions; technetium and iodine redox may vary from Tc to Tc and from I to I. Relatively few studies have been done on their speciation...

متن کامل

Minimal dosage of iodide required to suppress uptake of iodine-131 by normal thyroid.

Sodium iodide was given in increasing doses to mentally defective children with normal thyroid function. Maximal suppression of iodine-131 uptake was achieved with 1500 to 2000 micrograms of iodide per square meter of body surface per day, but quickly rebounded when iodide was discontinued. This minimal effective dose is important if countermeasures against fallout are employed.

متن کامل

Radionuclidic Purity – an Essential Parameter in Quality Control of Radiopharmaceuticals

Radiopharmaceuticals are radioactively labeled compounds fulfilling the requirements of pharmaceutical products, used in radio diagnosis or radiotherapy. One essential parameter in the quality control of radiopharmaceuticals is the radionuclidic purity. In this work, we present aspects regarding the radionuclidic purity determination for the radiopharmaceutical products: Sodium Iodide (I) solut...

متن کامل

Iodide kinetics and dosimetry in vivo after transfer of the human sodium iodide symporter gene in rat thyroid carcinoma cells.

UNLABELLED Transfer of the human sodium iodide symporter (hNIS) has been proposed as a new principle of cancer gene therapy. This study evaluates the iodide kinetics and dosimetry of iodide in hNIS-expressing thyroid carcinoma cells under optimized conditions. METHODS Using a bicistronic retroviral vector for the transfer of the hNIS and the hygromycin resistance gene, hNIS-expressing rat thy...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine technology

دوره 28 1  شماره 

صفحات  -

تاریخ انتشار 2000