[Coronary CT angiography using a prospective protocol. Comparison of image quality and radiation dose between dual source CT and single source CT].

نویسندگان

  • R Duarte
  • D Miranda
  • G Fernández-Pérez
  • J C Costa
چکیده

OBJECTIVE To compare the image quality and radiation dose in a group of patients undergoing coronary CT angiography using a 128-slice dual source helical CT scanner with high pitch alto and prospective acquisition with those in a group of patients with similar clinical characteristics undergoing coronary CT angiography using a 128-slice single-source CT scanner with prospective sequential acquisition. MATERIAL AND METHODS We included 80 patients with heart rates ≤65 beats/min: 40 underwent sequential 128-slice single source CT with prospective synchronization and the other 40 underwent 128-slice dual source helical CT with high pitch and prospective synchronization. Two radiologists independently assessed the quality of the images of the coronary arteries on the 80 coronary CT angiograms: image quality was classified on a four-point scale in which 1 represented excellent and 4 deficient. The effective dose of radiation was also calculated. RESULTS The clinical characteristics of the patients in the two groups were similar. The image quality obtained with dual source CT was significantly better than that obtained with single source CT (P=0.006). The mean effective dose of radiation in the group undergoing dual source CT was 36% lower than in the group undergoing single source CT (1.4±0.6 mSv vs. 2.2±0.9 mSv; P<0.01). CONCLUSION Although both sequential 128-slice single source CT with prospective acquisition and 128-slice dual source helical CT with high pitch and prospective acquisition provide good image quality and low effective doses of radiation, 128-slice dual source helical CT with prospective acquisition provides better image quality and results in a lower effective dose of radiation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prospective-triggered high-pitch spiral versus sequential dual-source CT coronary angiography: comparison of image quality and radiation dose

Background: Prospectively electrocardiography (ECG)-triggered high-pitch spiral coronary computed tomography angiography (CCTA) is a unique scan mode for dual-source CT (DSCT). Our reports aim to compare image quality and radiation dose of CCTA using high-pitch spiral or sequential acquisition mode in patients with low and stable heart rates. Materials and Methods: Patients with low and stable ...

متن کامل

Low kilovolt “prospective ECG-triggering” vs. “retrospective ECG-gating” coronary CTA: comparison of image quality and radiation dose

Background: To compare image quality and radiation doses of low kilovolt (kV) “prospective ECG-triggering” (PT) and standard “retrospective ECG-gating” (RG) coronary computed tomography (CT) angiography. Materials and Methods: A total of 101 consecutive patients (76 males, 25 females; mean age: 55.44 ± 8.28 years) with low-to-intermediate risk status for coronary artery disease and with a body ...

متن کامل

Clinical applications of virtual, non-contrast head images derived from dual-source, dual-energy cerebrovascular computed tomography angiography

Background: This study set out to evaluate the utility of cerebrovascular virtual non-contrast (VNC) scans. Materials and Methods: Conventional non-contrast (CNC) and dual-energy computed tomography angiography (DE-CTA) head scans were conducted on 100 subjects, of which 46 were normal, 15 had parenchymal hematomas of the brain, 13 had ischemic infarction, 22 had tumors, and 4 had calcified les...

متن کامل

Comparison of Image Quality of Low Voltage 64-slice Multidetector CT Angiography with the Standard Condition in Patients Suspected of Pulmonary Embolism

Introduction: Reduction of peak kilovoltage (kV) setting has been a useful approach to d creating radiation dose; however, it may have varied effects on noise and the accuracy of diagnosis. Thus, we compared image quality between low (80 kV) and standard kilovoltage (100 kV) protocols. Material and Methods: This triple blind non-randomized parallel quasi-experimental study was conducted on 140 ...

متن کامل

Optimization of Radiation Dose in Cranial Computed Tomography among Adults: Assessment of Radiation Dose against Image Quality

Introduction: The rapid use of computed tomography (CT) scan is of great concern, due to increase in patients’ dose. Optimization of CT protocol is a vital issue in dose reduction. This study aimed to optimize radiation dose in cranial CT and assess modifications in image quality under radiation dose reduction. Material and Methods: A poly(me...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiologia

دوره 55 4  شماره 

صفحات  -

تاریخ انتشار 2013