Snapshot Coronagraphy with an Interferometer in Space
ثبت نشده
چکیده
Diluted arrays of many optical apertures will be able to provide high-resolution snapshot images if the beams are combined according to the densified-pupil scheme. We show that the same principle can also provide coronagraphic images, for detecting faint sources near a bright unresolved one. Recent refinements of coronagraphic techniques, i.e. the use of a phase mask, active apodization and dark-speckle analysis, are also applicable for enhanced contrast. Implemented in the form of a proposed 50-500m Exo-Earth Discoverer array in space, the principle can serve to detect Earth-like exo-planets in the infra-red. It can also provide images of faint nebulosity near stars, active galactic nuclei and quasars. Calculations indicate that exo-planets are detectable amidst the zodiacal and exo-zodiacal emission faster than with a Bracewell array of equivalent area, a consequence of the spatial selectivity in the image.
منابع مشابه
Direct imaging with highly diluted apertures . I . Field of view limitations
Future optical interferometric instrumentation mainly relies on the availability of an efficient cophasing system: once available, what has so far postponed the relevance of direct imaging with an interferometer will vanish. This paper focuses on the actual limits of snapshot imaging, inherent to the use of a sparse aperture: the number of telescopes and the geometry of the array impose the max...
متن کاملTotal coronagraphic extinction of rectangular apertures using linear prolate apodizations
This paper presents a theoretical study of stellar coronagraphy with apodized entrance apertures. The study is restricted to a perfect telescope operating in space, and a monochromatic on-axis unresolved star. It is shown that linear prolate functions are the optimal apodizers for rectangular apertures in stellar coronagraphy. With the phase mask technique (Roddier & Roddier 1997), prolate func...
متن کاملElectrically switchable cylindrical Fresnel lens based on holographic polymer-dispersed liquid crystals using a Michelson interferometer
Fabricating an electrically switchable cylindrical Fresnel lens based on holographic polymer-dispersed liquid crystals (H-PDLC) using a Michelson interferometer is reported. Simplicity of the method and possibility of fabricating different focal length lenses in a single set up are among the advantages of the method. It is demonstrated that the Fresnel structured zone plate acts as a cylindrica...
متن کامل-
In this paper a method for digitally recording four quarter-reference-wave-holograms (by CCD) in a Mach-Zehnder interferometer setup, and reconstructing the object wave-front by numerical method is presented. The terms of direct transmission, auto-correlation and conjugate wave in the four wave reconstruction are cancelled out and only one original object wave is left after overlapping. Reconst...
متن کاملThe Magdalena Ridge Observatory Interferometer: a high sensitivity imaging array
The Magdalena Ridge Observatory Interferometer (MROI) is a US federally funded project to construct the world’s most ambitious optical/IR (0.6-2.4micron) imaging interferometer at a 10,500ft-altitude site in New Mexico. In its initial phase it will consist of 6 telescopes, each 1.4m in diameter, separated by distances ranging from 7.5m to 340m. A second phase will upgrade the interferometer to ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2000