Environmental testing of a blood gas/pH and electrolyte analyzer for field hospital use.

نویسنده

  • P M Dubill
چکیده

In 1983 the U.S. Army Academy of Health Sciences developed a Letter Requirement for a Blood Gas/pH Analyzer for use in Echelon 3 and 4 facilities. Field trials of several nondevelopment items and a subsequent market survey did not produce a suitable instrument. Recently, a relatively small, lightweight, and simple device became commercially available, and was tested for field applicability in accordance with MIL-STD-810D. Results indicated that with minor modifications, the instrument would be sufficiently rugged to withstand the severe storage temperature extremes and transit shock and vibration conditions associated with deployment of field medical materiel.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance of Gem Premier blood gas/electrolyte analyzer evaluated.

We evaluated a new analyzer designed for point-of-care testing of blood gases, sodium, potassium, ionized calcium, and hematocrit. The Gem Premier (Mallinckrodt) system has two components: the analyzer and a disposable cartridge. Analysis takes place in the cartridge, which contains the electrochemical sensors, the calibrants, the reagents, the sampling stylus, and the waste container. The syst...

متن کامل

Comparison of blood gas and electrolyte test results from the Gem-Premier and the ABL-70 versus a conventional laboratory analyzer.

Blood gas analyzers serve a critical role in providing information that reflects patient homeostasis. This study was undertaken to evaluate the accuracy, reliability, consistency, and bias of the Radiometer ABL-70 point of care blood gas analyzer. Thirty samples were gathered for analysis of pH, pCO2, pO2, sodium, potassium, sodium bicarbonate, and base excess. Twenty-nine samples were gathered...

متن کامل

Prehospital point of care testing of blood gases and electrolytes — an evaluation of IRMA

BACKGROUND: This study evaluated the feasibility of blood gas analysis and electrolyte measurements during emergency transport prior to hospital admission. RESULTS: A portable, battery-powered blood analyzer was used on patients in life threatening conditions to determine pH, pCO2, pO2, sodium, potassium and ionized calcium. Arterial blood was used for blood gas analysis and electrolyte measure...

متن کامل

Evaluation of the i-STAT Portable Clinical Analyzer for point-of-care blood testing in the intensive care units of a university children's hospital.

We evaluated the analytical performance of the i-STAT Portable Clinical Analyzer (PCA), a point-of-care testing system consisting of a hand-held analyzer and single-use cartridges that measure different panels of electrolytes, metabolites, blood gases, and hematocrit in 65-100 microl of blood. Our objective was to determine whether PCA measurements at the bedside of patients in the neonatal and...

متن کامل

Comparison of the point-of-care blood gas analyzer versus the laboratory auto-analyzer for the measurement of electrolytes

BACKGROUND Electrolyte values are measured both by arterial blood gas (ABG) analyzers and central laboratory auto-analyzers (AA), but a significant time gap exists between the availability of both these results, with the ABG giving faster results than the AA. The authors hypothesized that there is no difference between the results obtained after measurement of electrolytes by the blood gas and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Military medicine

دوره 155 11  شماره 

صفحات  -

تاریخ انتشار 1990