Carbon dioxide and oxygen partial pressure in expiratory water condensate are equivalent to mixed expired carbon dioxide and oxygen.

نویسندگان

  • W R von Pohle
  • J D Anholm
  • J McMillan
چکیده

This study was to determine whether the PCONCO2 and PCONO2 which collect in the expiratory trap of a ventilator circuit are equivalent to PECO2 and PEO2. Fifty studies were performed in 34 mechanically ventilated male patients. Five milliliters of condensate fluid were collected and PECO2 and PEO2 were measured. Exhaled gases were collected simultaneously with condensate fluid for 5 min in a meteorologic balloon and FECO2 and FEO2 were measured; PECO2 and PEO2 were then calculated. The mean PECO2 was not significantly different from PCONCO2 nor was the PCONO2 significantly different from the condensate PCONO2. There was a high correlation between mixed expired PECO2 and PCONCO2 as well as PEO2 and PCONO2. These data indicate expiratory PCONCO2 and PCONO2 provide a valid reflection of PECO2 and PEO2. The PCONCO2 and PCONO2 measured in a clinical blood gas analyzer are accurate and may be used in calculation of VD/VT and in metabolic assessments.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Chapter 32 – The Physiology of the Avian Embryo

Ap effective pore area CAM chorioallantoic membrane CO cardiac output CO2 carbon dioxide dCO2 carbon dioxide diffusion coefficient dH2O water vapor diffusion coefficient dO2 oxygen diffusion coefficient DO2 oxygen diffusing capacity EP external pipping FcOX mean corpuscular oxygenation velocity GCO2 carbon dioxide conductance GH2O water vapor conductance GO2 oxygen conductance Hb hemoglobin Hct...

متن کامل

Assessment of ventilation-perfusion mismatching in mechanically ventilated patients.

The multiple inert gas elimination technique (MIGET) is a robust tool to assess both ventilation-perfusion (V'A/Q') distributions and the role of extrapulmonary factors determining arterial oxygenation during spontaneous breathing and in mechanically ventilated patients. Mixed expired gas sampling used in the MIGET is most often obtained from a 10-L mixing box (10L-MB) placed in the expiratory ...

متن کامل

Carbon dioxide kinetics and capnography during critical care

Greater understanding of the pathophysiology of carbon dioxide kinetics during steady and nonsteady state should improve, we believe, clinical care during intensive care treatment. Capnography and the measurement of end-tidal partial pressure of carbon dioxide (PETCO2) will gradually be augmented by relatively new measurement methodology, including the volume of carbon dioxide exhaled per breat...

متن کامل

Cardiorespiratory responses to submaximal incremental exercise are not affected by one night's sleep deprivation during the follicular and luteal phases of the menstrual cycle.

The purpose of the study was to investigate the effects of one night's sleep deprivation on the cardiorespiratory responses to exercise during the follicular and luteal phases of the menstrual cycle. We have studied nine, healthy females aged 24-35 years with regular menstrual cycles. Each subject performed spirometric tests at rest and then an incremental exercise testing during 11-13 days of ...

متن کامل

Alveolar partial pressures of carbon dioxide and oxygen measured by a helium washout technique.

A non-invasive technique was developed for measuring alveolar carbon dioxide and oxygen tension during tidal breathing. This was achieved by solving the Bohr equations for mean alveolar carbon dioxide and oxygen tensions (PACO2, PAO2) from known values of the dead-space:tidal volume ratio measured by helium washout, and from the mixed expired partial pressure of carbon dioxide and oxygen. The d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Chest

دوره 101 6  شماره 

صفحات  -

تاریخ انتشار 1992