Evaluation of a novel point-of-care cryptococcal antigen test on serum, plasma, and urine from patients with HIV-associated cryptococcal meningitis.
نویسندگان
چکیده
BACKGROUND Many deaths from cryptococcal meningitis (CM) may be preventable through early diagnosis and treatment. An inexpensive point-of-care (POC) assay for use with urine or a drop of blood would facilitate early diagnosis of cryptococcal infection in resource-limited settings. We compared cryptococcal antigen (CRAG) concentrations in plasma, serum, and urine from patients with CM, using an antigen-capture assay for glucuronoxylomannan (GXM) and a novel POC dipstick test. METHODS GXM concentrations were determined in paired serum, plasma, and urine from 62 patients with active or recent CM, using a quantitative sandwich enzyme-linked immunosorbent assay (ELISA). A dipstick lateral-flow assay developed using the same monoclonal antibodies for the sandwich ELISA was tested in parallel. Correlation coefficients were calculated using Spearman rank test. RESULTS All patients had detectable GXM in serum, plasma, and urine using the quantitative ELISA. Comparison of paired serum and plasma showed identical results. There were strong correlations between GXM levels in serum/urine (r(s) = 0.86; P < .001) and plasma/urine (r(s) = 0.85; P < .001). Levels of GXM were 22-fold lower in urine than in serum/plasma. The dipstick test was positive in serum, plasma, and urine in 61 of 62 patients. Dipstick titers correlated strongly with ELISA. Correlations between the methods were 0.93 (P < .001) for serum, 0.94 (P < .001) for plasma, and 0.94 (P < .001) for urine. CONCLUSIONS This novel dipstick test has the potential to markedly improve early diagnosis of CM in many settings, enabling testing of urine in patients presenting to health care facilities in which lumbar puncture, or even blood sampling, is not feasible.
منابع مشابه
Evaluation of Fingerstick Cryptococcal Antigen Lateral Flow Assay in HIV-Infected Persons: A Diagnostic Accuracy Study
BACKGROUND Cryptococcus neoformans is the most common cause of adult meningitis in sub-Saharan Africa. The cryptococcal antigen (CRAG) lateral flow assay (LFA) has simplified diagnosis as a point-of-care test approved for serum or cerebrospinal fluid (CSF). We evaluated the accuracy of the CRAG LFA using fingerstick whole blood compared with serum/plasma and CSF for diagnosing meningitis. MET...
متن کاملPerformance of cryptococcal antigen lateral flow assay in serum, cerebrospinal fluid, whole blood, and urine in HIV-infected patients with culture-proven cryptococcal meningitis admitted at a Brazilian referral center
Cryptococcal meningitis is the most common cause of opportunistic meningitis in HIV-infected patients in Brazil and causes unacceptable high mortality rates. In this study, HIV-infected patients with a first episode of culture-proven cryptococcal meningitis in cerebrospinal fluid (CSF) were prospectively included in order to evaluate sensitivity of cryptococcal antigen (CrAg) lateral flow assay...
متن کاملPoint-of-care urine antigen screening tests for tuberculosis and cryptococcosis: potential for mortality reduction in antiretroviral treatment programs in Africa.
To the Editor—Between 8% and 26% of patients enrolling in antiretroviral treatment (ART) services in sub-Saharan Africa die within the first year of therapy, and a majority of these deaths occur within the first few months [1]. Mortality risk is particularly high among those with the lowest baseline CD4 cell counts, and tuberculosis and cryptococcal meningitis are leading causes [1]. Packages o...
متن کاملEvaluation of a point-of-care immunoassay test kit ‘StrongStep’ for cryptococcal antigen detection
BACKGROUND HIV-associated cryptococcal meningitis is the leading cause of adult meningitis in Sub-Saharan Africa, accounting for 15%-20% of AIDS-attributable mortality. The development of point-of-care assays has greatly improved the screening and diagnosis of cryptococcal disease. We evaluated a point-of-care immunoassay, StrongStep (Liming Bio, Nanjing, Jiangsu, China) lateral flow assay (LFA...
متن کاملUtility of urine and serum lateral flow assays to determine the prevalence and predictors of cryptococcal antigenemia in HIV-positive outpatients beginning antiretroviral therapy in Mwanza, Tanzania
BACKGROUND Detection of subclinical cryptococcal disease using cryptococcal antigen screening among HIV-positive individuals presents a potential opportunity for prevention of both clinical disease and death if patients with detectable cryptococcal antigen are identified and treated pre-emptively. Recently developed point-of-care cryptococcal antigen tests may be useful for screening, particula...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical infectious diseases : an official publication of the Infectious Diseases Society of America
دوره 53 10 شماره
صفحات -
تاریخ انتشار 2011