Electromagnetic Interference With Implantable Cardiac Devices
نویسنده
چکیده
Although pacemakers and implantable cardioverter-defibrillators (ICDs) are subject to electromagnetic interference (EMI) from many sources, relatively few are capable of causing clinically significant interference. However, in the rapidly evolving technology -driven environment in which we live, new devices that could theoretically cause interference with implanted devices constantly appear both within and outside the hospital environment. It is important that the clinician caring for a patient with an implanted device be aware of these sources to provide appropriate education and protection for the patient. Therefore, even if there are few new threats for the patient with a pacemaker or ICD in 2002, a review of the known sources of EMI is important.
منابع مشابه
Interference Between Cellular Telephones and Implantable Rhythm Devices: A Review on Recent Papers
BACKGROUND Cardiac pacemakers and implantable defibrillators are potentially susceptible to electromagnetic interferences as they have complex circuitry for sensing and communication purposes. Cellular telephones being an important source of electromagnetic waves are likely to cause interference in the function of these devices. METHODS A systematic analysis of studies on interaction between ...
متن کاملArrhythmia Management Devices
2799 According to a recent worldwide survey, current rates of de novo pacemaker and implantable cardioverter-defibrillator (ICD) implantation are higher than those of previous years at >700 000 and >200 000 per year, respectively. Parallel to the growth in cardiovascular implantable electronic device (CIED) use, technological advances have led to new sources of electromagnetic radiation. Modern...
متن کاملElectromagnetic interference with implantable cardioverter-defibrillators at power frequency: an in vivo study.
BACKGROUND The number of implantable cardioverter-defibrillators (ICDs) for the prevention of sudden cardiac death is continuing to increase. Given the technological complexity of ICDs, it is of critical importance to identify and control possible harmful electromagnetic interferences between various sources of electromagnetic fields and ICDs in daily life and occupational environments. METHO...
متن کاملInterference in implanted cardiac devices, Part I.
Sensing intrinsic cardiac electrical activity is essential for the function of pacemakers and implantable cardioverter defibrillators (ICDs). Examples of undesired triggering or inhibition of pacemaker output by extraneous signals were identified early after the introduction of noncompetitive, “demand” pacemakers. Hermetic shielding in metal cases, filtering, and interference rejection circuits...
متن کاملElectromagnetic Interference in Implantable Rhythm Devices - The Indian Scenario
Implantable rhythm device (IRD) is the generic name for the group of implantable devices used for diagnosis and treatment of cardiac arrhythmias. Devices in this category include cardiac pacemakers, implantable cardioverter defibrillators and implantable loop recorders. Since these devices have complex microelectronic circuitry and use electromagnetic waves for communication, they are susceptib...