Simple active method for reducing magnetic interference in a thermoelectrically cooled photomultiplier tube.
نویسندگان
چکیده
We present a simple modification for thermoelectrically cooled photomultiplier tube (PMT) assemblies that eliminates the magnetic interference between the peltier element and the PMT. An active compensation is accomplished by forming current loops of the wires of the peltier element and placing them in such a way that they eliminate the interfering magnetic field. It is demonstrated that the improved system reduces measurement errors of the order of 1% to statistical noise at the level of 0.07%.
منابع مشابه
Design and Study of Scintillator Crystals coupled to Silicon Photomultipliers for PET Application
A relatively new photodetector, the silicon photomultiplier (SiPM), is well suited for PET applications. It has similar sensitivity and gain to the industry standard photomultiplier tube (PMT), but has advantages such as smaller size and insensitivity to magnetic field. These properties make SiPMs an active area of research in the PET field. I will study a simplified setup, comprised of two ant...
متن کاملMonte-Carlo Simulation for an Aerogel Čerenkov Counter
We have developed a Monte-Carlo simulation code for an aerogel Čerenkov Counter which is operated under a strong magnetic field such as 1.5T. This code consists of two parts: photon transportation inside aerogel tiles, and one-dimensional amplification in a fine-mesh photomultiplier tube. It simulates the output photoelectron yields as accurately as 5% with only a single free parameter. This co...
متن کاملDevelopment of Si-PM Based Imaging Systems for Molecular Imaging
Silicon photomultiplier (Si-PM) is a promising photodetector for PET for the use in magnetic resonance imaging (MRI) systems because it is insensitive to static magnetic fields. Si-PM is also a promising for high resolution PET systems due to its small channels and high gain. We have developed several Si-PM based imaging systems for molecular imaging. First, we developed a high resolution Si-...
متن کاملH∞ Robust Controller Design and Experimental Analysis of Active Magnetic Bearings with Flexible Rotor System
H∞ controller for active magnetic bearings (AMBs) with flexible rotor system was designed in this paper. The motion equations of AMBs and flexible rotor system are built based on finite element methods (FEM). Weighting function matrices of H∞ controller for AMBs are studied for both the sensitivity and the complementary sensitivity of H∞ control theory. The simulation shows that the H∞ control ...
متن کاملStudy of Silicon Photomultipliers for Positron Emission Tomography (PET) Application
A relatively new photodetector, the silicon photomultiplier (SiPM), is well suited for PET applications. It has similar sensitivity and gain to the industry standard photomultiplier tube (PMT), but has advantages such as smaller size and insensitivity to magnetic field. These properties make this detector an active area of research in the PET field. I will study a simplified setup, comprised of...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Review of scientific instruments
دوره 79 4 شماره
صفحات -
تاریخ انتشار 2008