Diffusion in Tube Dialyzer
نویسنده
چکیده
Nowadays, kidney failure is a problem of many peoples in the world. We know that the main function of kidney is maintaining the chemical quality of blood particularly removing urea through urine. But when they malfunction, the pathologic state known as uremia results in a condition in which the urea is retained in the body. Failure of the kidney results in building up of harmful wastes and excess fluids in the body. Kidney diseases (failures) can be due to infections, high blood pressure (hypertension), diabetes, and/or extensive use of medication. The best form of treatment is the implantation of a healthy kidney from a donor. However, this is often not possible due to the limited availability of human organs. Chronic kidney failure requires the treatment using a tube dialyzer called dialysis. Blood is taken out of the body and passes through a special membrane that removes waste and extra fluids. The clean blood is then returned to the body. The process is controlled by a dialysis machine (tube dialyzer) which is equipped with a blood pump and monitoring systems to ensure safety. So this article investigates the real application of mathematics (diffusion) in medical science, and it also contains the mathematical formulation and interpretation of tube dialyzer in relation to diffusion.
منابع مشابه
Enhancement of Toxic Substances Clearance from Blood Equvalent Solution and Human Whole Blood through High Flux Dialyzer by 1 MHz Ultrasound
Background: Hemodialysis is a process of removing waste and excess fluid from blood when kidneys cannot function efficiently. It often involves diverting blood to the filter of the dialysis machin to be cleared of toxic substances. Fouling of pores in dialysis membrane caused by adhesion of plasma protein and other toxins will reduce the efficacy of the filtre.Objective: In This study, the infl...
متن کاملEffect of membrane potential on dialysis of calcium in a continuous-flow system.
Electical potentials across the membrane in a modified AutoAnalyzer dialyzer (Technicon) have been determined under various conditions and related to the dialysis of 45Ca. The results suggest that anomalies in the diffusion of calcium from protein and nonprotein containing streams could be due to factors other than "Donnan equilibrium effects."
متن کاملAn experimental and numerical study of the flow and mass transfer in a model of the wearable artificial kidney dialyzer
BACKGROUND Published studies of the past decades have established that mass transfer across the dialyzer membrane is governed by diffusion, convection and osmosis. While the former is independent of the pressure in the liquids, the latter two are pressure dependent and are enhanced when the pressure difference across the membrane is increased. The goal of the present study is to examine the imp...
متن کاملFinite Volume Scheme for Double Convection-Diffusion Exchange of Solutes in Bicarbonate High-Flux Hollow-Fiber Dialyzer Therapy
The efficiency of a high-flux dialyzer in terms of buffering and toxic solute removal largely depends on the ability to use convection-diffusion mechanism inside the membrane. A two-dimensional transient convection-diffusion model coupled with acid-base correction term was developed. A finite volume technique was used to discretize the model and to numerically simulate it using MATLAB software ...
متن کاملGeorg Haas (1886–1971): The Forgotten Hemodialysis Pioneer {December 2001}
The first human hemodialysis in the history of medicine was performed by Georg Haas in 1924 in the town of Giessen, Germany. The procedure lasted only 15 minutes, and hirudin served as the anticoagulant. Haas was able to develop a dialyzer consisting of U-shaped collodion tubes immersed in a dialysate bath placed in a glass cylinder. He performed several hemodialysis procedures in uremics betwe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 8 شماره
صفحات -
تاریخ انتشار 2017