Validation of fluorescent-labeled microspheres for measurement of regional organ perfusion.
نویسندگان
چکیده
Estimations of dog lung, pig heart, and pig kidney regional perfusion by use of fluorescent-labeled microspheres were compared with measurements obtained with standard radiolabeled microspheres. Pairs of radio- and fluorescent-labeled microspheres (15 microns diam, 6 colors) were injected into a central vein of a supine anesthetized dog and the left ventricle of three supine anesthetized pigs while reference blood samples were simultaneously withdrawn from a femoral artery in the pigs. The lungs were cubed into approximately 2 cm3 pieces (n = 1,510). Each pig heart and kidney was cubed into approximately 1-g pieces (total n = 192 and 120, respectively). The radioactivity of each organ piece and reference blood sample was determined using a scintillation counter with count rates corrected for decay, background, and spillover. Tissue samples and reference blood samples were digested with KOH and filtered and the fluorescent dye was extracted with a solvent, or the dye was extracted from lung tissue without filtering. The fluorescence of each sample was determined for each color by use of an automated spectrophotometer. Perfusion was calculated for each organ piece from both the radioactivity and fluorescence. Correlation between flow determined by radio- and fluorescent-labeled microspheres was as follows: r = 0.96 +/- 0.01 (SD) (lung, filtered, n = 588), r = 0.99 +/- 0.00 (lung, nonfiltered, n = 710), r = 0.95 +/- 0.02 (heart, filtered), and r = 0.96 +/- 0.02 (kidney, filtered). Compared with colored microspheres, methods for quantitating fluorescent-labeled microspheres are more sensitive, less labor intensive, and less expensive. Fluorescent-labeled microspheres provide a new nonradioactive method for single and repeated measurement of regional organ perfusion.
منابع مشابه
Validation of fluorescent microsphere technique for measurement of organ perfusion with simplified sample processing method abbreviated title: sedimentation technique for fluorescent microspheres
A disadvantage of non-radioactive microsphere techniques is that the processing of samples is time consuming and complex. We developed and validated a simplified processing method for the fluorescent microsphere (FM) technique. In 7 anesthetized dogs with coronary artery stenosis up to 6 different FM and 5 different radioactively labeled microspheres (RM) were injected, 2 FM and 2 RM labels bei...
متن کاملValidation of fluorescent-labeled microspheres for measurement of relative blood flow in severely injured lungs.
The aim of the study was to validate a nonradioactive method for relative blood flow measurements in severely injured lungs that avoids labor-intensive tissue processing. The use of fluorescent-labeled microspheres was compared with the standard radiolabeled-microsphere method. In seven sheep, lung injury was established by using oleic acid. Five pairs of radio- and fluorescent-labeled microsph...
متن کاملStable labeled microspheres to measure perfusion: validation of a neutron activation assay technique.
Neutron activation is an accurate analytic method in which trace quantities of isotopes of interest in a sample are activated and the emitted radiation is measured with high-resolution detection equipment. This study demonstrates the application of neutron activation for the measurement of myocardial perfusion using stable isotopically labeled microspheres. Stable labeled and standard radiolabe...
متن کاملHigh-resolution maps of regional ventilation utilizing inhaled fluorescent microspheres.
The regional deposition of an inhaled aerosol of 1.0-micron diameter fluorescent microspheres (FMS) was used to produce high-resolution maps of regional ventilation. Five anesthetized, prone, mechanically ventilated pigs received two 10-min inhalations of pairs of different FMS labels, accompanied by intravenous injection of 15.0-micron radioactive microspheres. The lungs were air dried and cut...
متن کاملMeasurement of regional myocardial perfusion and mass by subselective hydrogen infusion and washout techniques: a validation study.
A technique was developed for measuring regional myocardial perfusion by intracoronary infusions of hydrogen (H2)-saturated saline. H2 concentration was detected during washout in the pulmonary artery by means of the voltage response of a platinum-tipped electrode. Regional myocardial perfusion was calculated from the H2 exponential desaturation curve according to the Kety-Schmidt principle. In...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of applied physiology
دوره 74 5 شماره
صفحات -
تاریخ انتشار 1993