PURPOSE The natural lens may provide some compensatory optical effect in the periphery. When it is substituted by an IOL during cataract surgery, the quality of the peripheral optics will be modified. We compared the peripheral image quality in the eyes of patients with one eye implanted with a monofocal IOL and the fellow eye still with the natural precataract lens. METHODS We used a scanning peripheral Hartmann-Shack wavefront sensor to measure the central 80° of visual angle along the horizontal meridian. Twelve patients with ages ranging between 65 to 81 years were evaluated. The results of the phakic and pseudophakic eyes were compared using the spherical equivalent, astigmatism, higher order aberrations, and the Strehl ratio. The statistical differences at each angle between the two eyes were evaluated. RESULTS In the eyes implanted with IOLs, the peripheral mean spherical equivalent was slightly more myopic than in the phakic eyes, although the differences were only significant for some angles. Astigmatism increased much faster in the periphery for the pseudophakic eyes as compared with the phakic eyes. The mean values were significantly different from 9° and 17° outwards at the temporal and nasal retina, respectively. As an example, at 30°, eyes implanted with IOLs presented 1.5 diopters (D) of additional astigmatism. The higher order aberrations were not significantly different between the two groups. CONCLUSIONS Eyes implanted with monofocal IOLs present more astigmatism in the periphery than the healthy older eyes. This suggests that the crystalline lens provides a beneficial effect to partially compensate off-axis astigmatism. The degradation of the peripheral retinal image may reduce the pseudophakic patient's performance in common visual tasks.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Refractive lens exchange versus iris-claw Artisan phakic intraocular lens for hyperopia.

PURPOSE To study a paired-match comparison between refractive lens exchange with pseudophakic IOL implant (RLE) and Artisan phakic IOL for high hyperopia. METHODS Nineteen eyes (12 patients, 20 to 41 years old) with an Artisan phakic IOL (Model 203: 1.00-D increment) for hyperopia from +2.75 to +9.25 D were matched to 19 eyes (15 patients, 26 to 46 yr) with hyperopia from +2.75 to +7.50 D, wh...

متن کامل

A comparative assessment of endothelium from pseudophakic and phakic donor corneas stored in organ culture.

AIMS To evaluate the endothelial quality of corneas obtained from pseudophakic donors and to compare the data with matched phakic controls. METHODS Corneas from eyes with posterior chamber intraocular lenses (PCIOLs) and corneas from phakic eyes (controls) were stored for 1-2 weeks in organ culture and then examined after staining with Alizarin red S. The corneas were divided into two groups ...

متن کامل

Comparison of intravitreal bevacizumab treatment between phakic and pseudophakic neovascular age-related macular degeneration.

INTRODUCTION Before the era of intravitreal anti-vascular endothelial growth factor (anti-VEGF) treatment, only prevention for visual loss might have been achieved in a limited number of neovascular age-related macular generation (nAMD) patients with different treatment options. OBJECTIVE To compare the efficacy of intravitreal bevacizumab (IVB) for the treatment of nAMD between phakic and ps...

متن کامل

Trabeculectomy for open-angle glaucoma in phakic eyes vs in pseudophakic eyes after phacoemulsification: a prospective clinical cohort study.

IMPORTANCE Whether pseudophakic eyes are resistant to trabeculectomy remains unknown. OBJECTIVE To determine the effect of previous phacoemulsification on surgical success of trabeculectomy with mitomycin C for open-angle glaucoma. DESIGN, SETTING, AND PARTICIPANTS Prospective clinical cohort study at Kumamoto University Hospital, Kumamoto, Japan, among patients 55 years or older having ope...

متن کامل

Effect of chromatic aberration on contrast sensitivity in pseudophakic eyes.

OBJECTIVE To evaluate the effect of chromatic aberrations in pseudophakic eyes with various types of intraocular lenses (IOLs). PATIENTS AND METHODS The study included 51 eyes of 33 patients who underwent cataract surgery. The eyes were divided into 3 groups according to the material from which their IOL was made: group 1, polymethyl methacrylate; group 2, silicone; and group 3, an acrylate/m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 54 5  شماره 

صفحات  -

تاریخ انتشار 2013