Severe symptomatic tricuspid valve regurgitation due to permanent pacemaker or implantable cardioverter-defibrillator leads.

نویسندگان

  • Grace Lin
  • Rick A Nishimura
  • Heidi M Connolly
  • Joseph A Dearani
  • Thoralf M Sundt
  • David L Hayes
چکیده

OBJECTIVES We report a series of patients with severe tricuspid valve regurgitation due to a permanent pacemaker (PPM) or implantable cardioverter-defibrillator (ICD) lead. BACKGROUND Severe tricuspid regurgitation caused by a PPM or ICD lead is an under-recognized but treatable etiology of severe right heart failure. METHODS We reviewed the records of 41 patients who underwent tricuspid valve operation for severe tricuspid regurgitation caused by previously placed PPM or ICD leads. RESULTS During surgery, severe tricuspid regurgitation was found to be caused by the PPM or ICD leads in all 41 patients. There was a perforation of the tricuspid valve leaflet by the PPM or ICD lead in 7 patients, lead entanglement in the tricuspid valve occurred in 4 patients, lead impingement of the tricuspid valve leaflets occurred in 16 patients, and lead adherence to the tricuspid valve occurred in 14 patients. The septal leaflet was most often perforated (6 of 7). In the preoperative evaluation, valve malfunction due to the PPM or ICD lead was diagnosed preoperatively in only 5 of 41 (12%) patients by transthoracic echocardiography. All patients underwent successful tricuspid valve operation (22 tricuspid valve replacement), with one perioperative death occurring. During follow-up (range, 1 to 99 months), there was one patient who died from left-sided heart failure and three patients died of other causes. The remaining patients showed improvement in signs and symptoms of heart failure. CONCLUSIONS Damage to the tricuspid valve by PPM or ICD leads may result in severe symptomatic tricuspid regurgitation and may not be overtly visualized by echocardiography. This etiology should be considered when evaluating patients with severe right heart failure after PPM or ICD implantation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical utility of 3-dimensional echocardiography in the evaluation of tricuspid regurgitation caused by pacemaker leads.

BACKGROUND This study evaluated the usefulness of 3-dimensional echocardiography (3-DE) for identifying permanent pacemaker (PPM) or implantable cardioverter defibrillator (ICD) lead-related symptomatic tricuspid regurgitation (TR). METHODS AND RESULTS Eighty-seven patients underwent 3-DE examination: 50 patients with PPM, 17 with ICD, and 20 with cardiac resynchronization therapy devices. TR...

متن کامل

Is correction for metallic artefacts mandatory in cardiac SPECT/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?

Introduction: Metallic artifacts due to pacemaker/ implantable cardioverter defibrillator (ICD) leads in CT images can produce artifactual uptake in cardiac SPECT/CT images. The aim of this study was to determine the influence of the metallic artifacts due to pacemaker and ICD leads on myocardial SPECT/CT imaging. Methods: The study included 9 patients wh...

متن کامل

Rare Cause of Pacemaker Lead Interference: Tricuspid Valve Myxoma

Introduction: Primary tumors of the heart are a rare finding, and the most common benign tumors are cardiac myxomas, accounting for up to 80% of cases. They are of endocardial origin therefore the prevalence of myxomas in the atrial septum is highest. Among myxomas left atrial ones are the most common (75%), followed by right atrial ones (18%). Case Presentation: We present a case of a cardiac ...

متن کامل

Anesthetic management of a patient with hypertrophic obstructive cardiomyopathy undergoing modified radical mastectomy.

Hypertrophic obstructive cardiomyopathy (HOCM) is a rare genetic disorder characterized by left ventricular outflow tract (LVOT) obstruction. Clinical presentation ranges from absence of symptoms to sudden death. Our 60 year old patient scheduled for left modified radical mastectomy had HOCM since seventeen years with severe LVOT obstruction and mitral regurgitation. An implantable cardioverter...

متن کامل

Defibrillator-Induced Tricuspid Abscess Presenting as Diabetic Ketoacidosis and Wound Ulceration

Right-sided endocarditis is predominantly seen in patients with a history of intravenous drug abuse. However, it is well shown in the literature to be associated with patients containing foreign bodies such as pacemakers, central venous lines, and in those with congenital heart disease. In patients with pacemaker leads and in those with automatic implantable cardioverter defibrillators (AICDs),...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 45 10  شماره 

صفحات  -

تاریخ انتشار 2005