Resonant ultrasound spectroscopy measurements of the elastic constants of human dentin.

نویسندگان

  • J H Kinney
  • J R Gladden
  • G W Marshall
  • S J Marshall
  • J H So
  • J D Maynard
چکیده

The technique of resonant ultrasound spectroscopy (RUS) was used to measure the second-order elastic constants of hydrated human dentin. Specimens were placed between two transducers, and the resonant frequencies of vibration were measured between 0.5 and 1.4 MHz. The elastic constants determined from the measured resonant frequencies in hydrated dentin exhibited slight hexagonal anisotropy, with the stiffest direction being perpendicular to the axis of the tubules (E11 = 25.1GPA) This hexagonal anisotropy was small (E33/E11 = 0.92), and almost disappeared when the specimens were dried. In addition, there was a pronounced anisotropy in the Poisson's ratio of wet dentin: v21 = 0.45; v31 = 0.29. With drying in air, this anisotropy vanished: v21 = v31 = 0.29. The isotropic Young's modulus of dried dentin was 28.1 GPa. RUS shows promise for determining the elastic constants in mineralized tissues.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measuring Dislocation Density in aluminum with Resonant Ultrasound Spectroscopy

Dislocations in a material will, when present in enough numbers, change the speed of propagation of elastic waves. Consequently, two material samples, differing only in dislocation density, will have different elastic constants, a quantity that can be measured using Resonant Ultrasound Spectroscopy. Measurements of this effect on aluminum samples are reported. They compare well with the predict...

متن کامل

Measurements of elastic constants in thin films of colossal magnetoresistance material.

Measurements of elastic constants of strained 200 and 400 nm thin films, as well as unstrained samples, of the colossal magnetoresistance (CMR) material La0.67Ca0.33MnO3 are presented. Since the peak resistance temperature of a strained CMR film decreases as the film thickness decreases, it is of interest to see if features in the elastic constants, reflecting structural or magnetic changes, fo...

متن کامل

The Elasticity Coefficients Measurement of Human Dentin Based on RUS

This paper proposed to take advantages of resonant ultrasound spectroscopy (RUS) to measure the mechanical properties of human dentin specimen. The resonant spectroscopy of the dentin specimen was obtained between the frequency bands 155 and 575 kHz, and resonant frequencies were extracted by linear predictive filter and then by Levenberg-Marquardt method. By inverse problem approach, 13 experi...

متن کامل

Elastic tensor of Sr2RuO4

The six independent elastic constants of Sr2RuO4 were determined using resonant ultrasound spectroscopy on a high-quality single-crystal specimen. The constants are in excellent agreement with those obtained from pulse-echo experiments performed on a sample cut from the same ingot. A calculation of the Debye temperature using the measured constants agrees well with values obtained from both spe...

متن کامل

Bayesian inference of elastic properties with resonant ultrasound spectroscopy.

Bayesian modeling and Hamiltonian Monte Carlo (HMC) are utilized to formulate a robust algorithm capable of simultaneously estimating anisotropic elastic properties and crystallographic orientation of a specimen from a list of measured resonance frequencies collected via Resonance Ultrasound Spectroscopy (RUS). Unlike typical optimization procedures which yield point estimates of the unknown pa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomechanics

دوره 37 4  شماره 

صفحات  -

تاریخ انتشار 2004