New Decision Criteria for Selecting Delta Check Methods Based on the Ratio of the Delta Difference to the Width of the Reference Range Can Be Generally Applicable for Each Clinical Chemistry Test Item
نویسندگان
چکیده
BACKGROUND Many laboratories use 4 delta check methods: delta difference, delta percent change, rate difference, and rate percent change. However, guidelines regarding decision criteria for selecting delta check methods have not yet been provided. We present new decision criteria for selecting delta check methods for each clinical chemistry test item. METHODS We collected 811,920 and 669,750 paired (present and previous) test results for 27 clinical chemistry test items from inpatients and outpatients, respectively. We devised new decision criteria for the selection of delta check methods based on the ratio of the delta difference to the width of the reference range (DD/RR). Delta check methods based on these criteria were compared with those based on the CV% of the absolute delta difference (ADD) as well as those reported in 2 previous studies. RESULTS The delta check methods suggested by new decision criteria based on the DD/RR ratio corresponded well with those based on the CV% of the ADD except for only 2 items each in inpatients and outpatients. Delta check methods based on the DD/RR ratio also corresponded with those suggested in the 2 previous studies, except for 1 and 7 items in inpatients and outpatients, respectively. CONCLUSIONS The DD/RR method appears to yield more feasible and intuitive selection criteria and can easily explain changes in the results by reflecting both the biological variation of the test item and the clinical characteristics of patients in each laboratory. We suggest this as a measure to determine delta check methods.
منابع مشابه
Differential application of rate and delta check on selected clinical chemistry tests.
Through the present delta value check used in quality control programs is a powerful tool for detecting random errors in clinical chemistry analysis, it has some problems, such as missed true errors and delays in reporting time, because it also has the potential of showing erroneous positive results. Recently, new calculation methods for delta check with delta difference, delta percent change, ...
متن کاملAnalysis of Hazard Identification Methods in Process Industries Using Analytic Network Process Technique (ANP)
Background and aims: Hazard identification is a critical factor to ensure safe design and operation of systems in the process industries. Process industries are one of the most complex systems, with a variety of equipment, control systems, and executive procedures. In these industries, the use of hazardous materials as raw materials or products is quite common. Interactions between technical co...
متن کاملTime-Mode Signal Quantization for Use in Sigma-Delta Modulators
The rapid scaling in modern CMOS technology has motivated the researchers to design new analog-to-digital converter (ADC) architectures that can properly work in lower supply voltage. An exchanging the data quantization procedure from the amplitude to the time domain, can be a promising alternative well adapt with the technology scaling. This paper is going to review the recent development in t...
متن کاملExperimental Investigation of Asymmetry of Vortex Flow Over Single Delta Wings
It is generally believed that, on slender delta wings, there is a critical state at which strong asymmetric vortices are found along the leading edge on the lee-side of the delta wing. These asymmetric vortices can lead to high lateral forces even when slender delta wing is at the zero angle of yaw. Some experimental studies reported recently, cast considerable doubt as to the validity of the a...
متن کاملEffects of agro-chemicals on fishes: With reference to changes in circulating biochemical parameters in Clarias gariepinus induced with Paraquat dichloride
The response of Clarias gariepinus to Paraquat dichloride, a herbicide that is in high demand in the fragile Niger Delta ecological zone was investigated. The herbicide had been detected in most of the water bodies in the region. The fishes were exposed to the range of concentrations observed in the field (0, 2, 4, 6 and 8) µg/L for 28 days, conducted under the Organization for Economic Co-oper...
متن کامل