Nose-only versus whole-body aerosol exposure for induction of upper respiratory infections of laboratory mice.
نویسندگان
چکیده
The effectiveness of two aerosol delivery systems, nose-only and whole-body, were compared using Swiss-Webster mice and two pathogens, Klebsiella pneumoniae and Venezuelan equine encephalitis (VEE) virus. With K. pneumoniae the median lethal dose (LD50) and the mean time to death correlated with the inhaled dose. An LD50 value of 335 colony forming units (cfu) for nose-only exposure was significantly less than the LD50 value of 3741 cfu obtained for whole-body exposure. The LD50 values obtained with VEE virus for nose-only exposure [8 plaque forming units (pfu)] and whole-body exposure (11 pfu) were similar to each other. Following a 10-min nose-only exposure, concentrations of K. pneumoniae approximating 10(4)/g were present after 24 hr in the upper respiratory tract (URT) and lungs. The numbers of bacteria reached a peak at 72 hr, when resolution of the infection began. Detectable levels of bacteria in the blood and tissues were delayed in mice given whole-body exposure, plus there was a decreased concentration of bacteria per gram of tissue. Major pathological lesions induced by K. pneumoniae were mild suppurative rhinitis and minimal suppurative bronchopneumonia. Viremia was greatest at 96 hr following aerosol exposure to VEE. Virus concentrations in the URT, lungs, cerebrum, spleen and mesenteric lymph nodes reached maximum titers earlier for mice exposed by nose-only than for mice exposed to whole-body aerosols.(ABSTRACT TRUNCATED AT 250 WORDS)
منابع مشابه
Gene Expression and Pulmonary Toxicity of Chitosan-graft-Polyethylenimine as Aerosol Gene Carrier
Chitosan-graft-polyethylenimine (CHI-g-PEI) copolymer has been used for theimprovement of low transfection efficiency of chitosan. The present study aims to test thepulmonary toxicity and efficiency of CHI-g-PEI as an aerosol gene carrier. Mice were exposedto aerosol containing green-fluorescent protein (GFP)-polyethylenimine (PEI) or GFP-CHIg-PEI complexes for 30 min during the development of ...
متن کاملGene Expression and Pulmonary Toxicity of Chitosan-graft-Polyethylenimine as Aerosol Gene Carrier
Chitosan-graft-polyethylenimine (CHI-g-PEI) copolymer has been used for theimprovement of low transfection efficiency of chitosan. The present study aims to test thepulmonary toxicity and efficiency of CHI-g-PEI as an aerosol gene carrier. Mice were exposedto aerosol containing green-fluorescent protein (GFP)-polyethylenimine (PEI) or GFP-CHIg-PEI complexes for 30 min during the development of ...
متن کاملAlterations in salivary IgA levels in infectious and inflammatory disorders of upper respiratory tract
Background: The airway surfaces are one of the most common ways of entry of infectious agents. Oral cavity associated lymphoid tissues are inductive site of humoral immune responses in inflammatory and infectious disorders of the upper respiratory tract. These lymphoid tissues play important roles in the induction of salivary IgA. The impact of upper respiratory tract diseases on salivary IgA p...
متن کاملAerosol and nasal transmission of chronic wasting disease in cervidized mice
Little is known regarding the potential risk posed by aerosolized prions. Chronic wasting disease (CWD) is transmitted horizontally, almost surely by mucosal exposure, and CWD prions are present in saliva and urine of infected animals. However, whether CWD may be transmissible by the aerosol or nasal route is not known. To address this question, FVB mice transgenetically expressing the normal c...
متن کاملDevelopment of an aerosol model of murine respiratory mycoplasmosis in mice.
Animal models of murine respiratory mycoplasmosis due to Mycoplasma pulmonis provide excellent opportunities to study respiratory disease due to an infectious agent. The purpose of the present study was to develop and characterize an aerosol model for the production of murine respiratory mycoplasmosis in mice. The exposure of mice for 30 min to aerosols generated with a DeVilbiss 45 nebulizer i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- American Industrial Hygiene Association journal
دوره 49 3 شماره
صفحات -
تاریخ انتشار 1988