A prospective randomised study comparing TightRope and syndesmotic screw fixation for accuracy and maintenance of syndesmotic reduction assessed with bilateral computed tomography.
نویسندگان
چکیده
BACKGROUND The accuracy and maintenance of syndesmosis reduction are essential when treating ankle fractures with accompanying syndesmosis injuries. The primary aim of this study was to compare syndesmosis screw and TightRope fixation in terms of accuracy and maintenance of syndesmosis reduction using bilateral computed tomography (CT). STUDY DESIGN Single centre, prospective randomised controlled clinical trial; Level of evidence 1. METHODS This study (ClinicalTrials.gov, NCT01742650) compared fixation with TightRope(®) (Arthrex, Naples, FL, USA) or with one 3.5-mm tricortical trans-syndesmotic screw in terms of accuracy and maintenance of syndesmosis reduction in Lauge-Hansen pronation external rotation, Weber C-type ankle fractures with associated syndesmosis injury. Twenty-one patients were randomised to TightRope fixation and 22 to syndesmotic screw fixation. Syndesmosis reduction was assessed using bilateral CT intraoperatively or postoperatively, and also at least 2 years after surgery. Functional outcomes and quality of life were assessed using the Olerud-Molander score, a 100-mm Visual Analogue Scale, the Foot and Ankle Outcome Score, and the RAND 36-Item Health Survey. Grade of osteoarthritis was qualified with follow-up cone-beam CT. RESULTS According to surgeons' assessment from intraoperative CT, screw fixation resulted in syndesmosis malreduction in one case whereas seven syndesmosis were considered malreduced when TightRope was used. However, open exploration and postoperative CT of these seven cases revealed that syndesmosis was well reduced if the ankle was supported at 90˚. Retrospective analysis of the intra- and post-operative CT by a radiologist showed that one patient in each group had incongruent syndesmosis. Follow-up CT identified three patients with malreduced syndesmosis in the syndesmotic screw fixation group, whereas malreduction was seen in one patient in the TightRope group (P = 0.33). Functional scores and the incidence of osteoarthritis showed no significant difference between groups. CONCLUSION Syndesmotic screw and TightRope had similar postoperative malreduction rates. However, intraoperative CT scanning of ankles with TightRope fixation was misleading due to dynamic nature of the fixation. After at least 2 years of follow-up, malreduction rates may slightly increase when using trans-syndesmotic screw fixation, but reduction was well maintained when fixed with TightRope. Neither the incidence of ankle joint osteoarthritis nor functional outcome significantly differed between the fixation methods.
منابع مشابه
Syndesmotic InternalBraceTM for anatomic distal tibiofibular ligament augmentation
Reconstruction of unstable syndesmotic injuries is not trivial, and there is no generally accepted treatment guidelines. Thus, there still remain considerable controversies regarding diagnosis, classification and treatment of syndesmotic injuries. Syndesmotic malreduction is the most common indication for early re-operation after ankle fracture surgery, and widening of the ankle mortise by only...
متن کاملCHAPTER 9 TECHNIQUE , OF SYI \ DESMOTIC REPAIR : Investigating the Innovative Tightrope ' * in Treatment of Syndesmotic Injuries
Fractures of the adult anlde with disruption of the tibiofibular syndesmosis call for sufficient stabilization of the ankle mortise to ensure proper healing of the syndesmotic ligaments. Several internal fixation techniques for stabilization of the syndesmosis have been employed in the past, including 3.5 mm, 4.5 mm, and 5.0 mm metallic and bioabsorbable screws, 1.5 mm and 1.5 mm Kirschner wire...
متن کاملA reliable method for intraoperative evaluation of syndesmotic reduction.
OBJECTIVES To determine the accuracy of a technique for intraoperative assessment of syndesmotic reduction in ankle fractures. DESIGN Prospective, case series. SETTING University hospital. PATIENTS/PARTICIPANTS Eighteen consecutive patients with suspected syndesmotic injuries were enrolled between 2007 and 2009. The diagnosis of syndesmotic injury was based on static ankle radiographs. Th...
متن کاملOvertightening of the syndesmosis revisited and the effect of syndesmotic malreduction on ankle dorsiflexion.
BACKGROUND Ankle syndesmotic injuries are a significant source of morbidity and require anatomic reduction to optimize outcomes. Although a previous study concluded that maximal dorsiflexion during syndesmotic fixation was not required, methodologic weaknesses existed and several studies have demonstrated improved ankle dorsiflexion after removal of syndesmotic screws. The purposes of the curre...
متن کاملBiomechanical Comparison of Distal Tibiofibular Syndesmotic Joint Fixation: Novel Suture Construct versus Metallic Screw Construct in Syndesmotic Injury Model
INTRODUCTION: Syndesmotic injuries of the ankle commonly occur via an external rotation force applied to the ankle joint. The effects of rigid or non-rigid fixation of the syndesmotic injury can be assessed by evaluating the three-dimensional kinematics behavior of tibiofibular diastasis. The specific aims of this study were: 1) to determine the physiological range of motion of the distal tibio...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Injury
دوره 46 6 شماره
صفحات -
تاریخ انتشار 2015