Effect of specimen size on microCT cortical tissue measurements

نویسندگان

  • L. Mecozzi
  • F. Particelli
  • A. Beraudi
  • M. Montesi
  • F. Baruffaldi
چکیده

Aims The increasing interest in cortical bone strenght [1,2] led up to the investigation of the cortical tissue through X-ray microcomputed tomography (microCT). In the past histology has been the gold standard for the morphometric examination of bone specimens but this new method permits the non-destructive analyses of specimens in a faster way preserving the integrity of the samples [3] and the calculation of the morphometric parameters over the whole sample’s volume. The accuracy of microCT bone measurements can be influenced by a segmentation method that, through a threshold value, separates “bone” from “non bone” in the reconstructed grayscale datasets. In order to validate the characterization of human cortical bone microarchitecture using micro-CT, cortical measures were compared with those obtained through histological examination [4,5]. Since studies often compare samples with a range of different sizes, the accurate measurement in specimens of unequal size is important. The aim of this work was to compare microtomographic and histological analyses of cortical bone specimens of two different sizes, and to investigate how cortical measures are affected by errors when a different threshold value is applied.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of integration time on the morphometric, densitometric and mechanical properties of the mouse tibia.

Micro-Computed Tomography (microCT) images are used to measure morphometric and densitometric properties of bone, and to develop finite element (FE) models to estimate mechanical properties. However, there are concerns about the invasiveness of microCT imaging due to the X-rays ionising radiation induced by the repeated scans on the same animal. Therefore, the best compromise between radiation ...

متن کامل

Specimen size and porosity can introduce error into microCT-based tissue mineral density measurements.

The accurate measurement of tissue mineral density, rho(m), in specimens of unequal size or quantities of bone mineral using polychromatic microCT systems is important, since studies often compare samples with a range of sizes and bone densities. We assessed the influence of object size on microCT measurements of rho(m) using (1) hydroxyapatite rods (HA), (2) precision-manufactured aluminum foa...

متن کامل

Quantitative micro-computed tomography: a non-invasive method to assess equivalent bone mineral density.

One of the many applications of micro computed tomography (microCT) is to accurately visualize and quantify cancellous bone microstructure. However, microCT based assessment of bone mineral density has yet to be thoroughly investigated. Specifically, the effects of varying imaging parameters, such as tube voltage (kVp), current (microA), integration time (ms), object to X-ray source distance (m...

متن کامل

Beam hardening artifacts in micro-computed tomography scanning can be reduced by X-ray beam filtration and the resulting images can be used to accurately measure BMD.

Bone mineral density (BMD) measurements are critical in many research studies investigating skeletal integrity. For pre-clinical research, micro-computed tomography (microCT) has become an essential tool in these studies. However, the ability to measure the BMD directly from microCT images can be biased by artifacts, such as beam hardening, in the image. This three-part study was designed to un...

متن کامل

Guidelines for assessment of bone microstructure in rodents using micro-computed tomography.

Use of high-resolution micro-computed tomography (microCT) imaging to assess trabecular and cortical bone morphology has grown immensely. There are several commercially available microCT systems, each with different approaches to image acquisition, evaluation, and reporting of outcomes. This lack of consistency makes it difficult to interpret reported results and to compare findings across diff...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013