SU-E-T-609: Improving the Efficiency of VMAT Plan Optimization by Using Sparse Decomposition Method.

نویسندگان

  • Y Na
  • T Suh
  • L Xing
چکیده

PURPOSE Volumetric modulated arc therapy (VMAT) is capable of delivering highly conformable dose distribution efficiently. Its planning is, however, more computationally intensive and requires a huge amount of memory space for optimization. We present an efficient sparse decomposition method for VMAT plan optimization. METHODS A quadratic objective function with volumetric constraints is expressed as a function of the aperture shapes and weights of the incident beams. The algorithm generates a sequence of iterates to solve the optimization problem. Each step of iteratively reweighed method is to be updated by solving the subproblem involving a quadratic (L2) term and a sparsity-inducing regulation (L1) term. Through the sparse decomposition techniques of the given problem, the deliverable apertures are directly generated. The shape of each aperture is iteratively rectified to be a sequencing of arc using the manufacture constraints. An initial arc spacing of 8 degree creates 45 beams directions for a single arc, 360 degree. The angular separation is equispaced every 2 degree over the end of optimization cycle. The optimization is implemented for a Varian TrueBeamTM STX linac beams with and without flattening filters available. Three clinical cases, head and neck, lung, and prostate, have been studied for the purpose of evaluating the planning efficiency and quality of the plans. RESULTS The target dose coverage and critical structure sparing of VMAT plan are comparable to those of IMRT plans. The VMAT plan delivers lower doses to other OARs while keeping the similar target dose coverage to IMRT plan. The VMAT plan optimizations takes less than 3 minutes on average of the cases indicating great efficiency compared to existing methods. CONCLUSIONS The results demonstrate that the proposed method provides competent computational efficiency for optimizing VMAT plan. The method substantially improves the speed and accuracy of VMAT plan optimization and makes future on-treatment adaptive re-planning possible.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

SU-E-T-619: A Network-Flow Solution Approach to VMAT Treatment Plan Optimization.

PURPOSE To add mathematical rigor to the merging phase of the recently published two-stage VMAT optimization method called VMERGE. Using an exact merging method, we are able to better characterize the tradeoff between delivery efficiency and dose quality. METHODS VMERGE begins with an IMRT plan that uses 180 equi-spaced beams and yields the "ideal" dose. Neighboring fluence maps are successiv...

متن کامل

Optimal partial-arcs in VMAT treatment planning.

We present a method for improving the delivery efficiency of VMAT by extending the recently published VMAT treatment planning algorithm vmerge to automatically generate optimal partial-arc plans. A high-quality initial plan is created by solving a convex multicriteria optimization problem using 180 equi-spaced beams. This initial plan is used to form a set of dose constraints, and a set of part...

متن کامل

Volumetric‐modulated arc therapy using multicriteria optimization for body and extremity sarcoma

This study evaluates the implementation of volumetric-modulated arc therapy (VMAT) using multicriteria optimization (MCO) in the RayStation treatment planning system (TPS) for complex sites, namely extremity and body sarcoma. The VMAT-MCO algorithm implemented in RayStation is newly developed and requires an integrated, comprehensive analysis of plan generation, delivery, and treatment efficien...

متن کامل

Evaluation of a fast method of EPID-based dosimetry for IMRT and Comparison with 3D EPID-based dosimetry system using conventional two- and three-dimensional detectors for VMAT

Introduction: Electronic portal imaging devices (EPIDs) could potentially be useful for intensity-modulated radiation therapy (IMRT) and VMAT QA. The data density, high resolution, large active area, and efficiency of the MV EPID make it an attractive option. However, EPIDs were designed as imaging devices, not dosimeters, and as a result they do not inherently measure dose in ...

متن کامل

Efficiency of biological versus physical optimization for single‐arc VMAT for prostate and head and neck cases

The aim of this work was to compare different approaches to VMAT optimization (biological vs. physical DVH-based) in two commercial treatment planning systems (TPS) for head and neck and prostate cases, using Pareto fronts. VMAT vs. IMRT Pareto front comparison was additionally performed in order to benchmark the optimizer efficiency and VMAT plan quality for each TPS. Three prostate and three ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 39 6Part19  شماره 

صفحات  -

تاریخ انتشار 2012