Ultrasound-guided catheterization of the internal jugular vein.
نویسندگان
چکیده
AIM To compare the traditional anatomic landmark technique with the ultrasound-guided method for central venous catheterization. MATERIAL AND METHODS During three years, 551 patients underwent internal jugular vein catheterization; in 347 patients, the ultrasound-guided technique was used, while in the other 204 patients the catheter was introduced by using the classical anatomic landmark method. Operating time, complications (pneumothorax, puncture of carotid artery with or without hematoma formation), and number of attempts to achieve central venous catheterization were recorded. RESULTS The ultrasound-guided technique was associated with significantly shorter operating time (9.83+/-3.1 vs. 20+/-4.4 min, p<0.001) and less morbidity (pneumothorax, 0 vs. 2 patients [p<0.05], carotid artery puncture with or without hematoma formation, 1 vs. 16 patients [p<0.05]). Moreover, the ultrasound-guided technique was highly successful in achieving central venous catheterization (failure, 0 vs. 18 patients [p<0.05]), with significantly fewer attempts (1-3 attempts in 204 vs. 283 [p<0.01]), compared to the classical anatomic landmark technique. CONCLUSION The ultrasound-guided method is faster, more efficient, and less morbid procedure compared with the classical anatomic landmark technique. Therefore, it should be preferred over the classical landmark method, especially in high-risk patients for the development of complications.
منابع مشابه
Internal Jugular Vein Cannulation: An Ultrasound-Guided Technique Versus a Landmark-Guided Technique
OBJECTIVES To compare the landmark-guided technique versus the ultrasound-guided technique for internal jugular vein cannulation in spontaneously breathing patients. METHODS A total of 380 patients who required internal jugular vein cannulation were randomly assigned to receive internal jugular vein cannulation using either the landmark- or ultrasound-guided technique in Bursa, Uludag Univers...
متن کاملAn Ultrasound Study of Cerebral Venous Drainage after Internal Jugular Vein Catheterization
Objectives. It has been advocated that internal jugular vein (IJV) cannulation in patients at risk for intracranial hypertension could impair cerebral venous return. Aim of this study was to demonstrate that ultrasound-guided IJV cannulation in elective neurosurgical patients is safe and does not impair cerebral venous return. Methods. IJV cross-sectional diameter and flow were measured using t...
متن کاملUltrasound-guided internal jugular vein catheterization in critically ill pediatric patients
PURPOSE Continuous intravenous access is imperative in emergency situations. Ultrasound-guided internal jugular vein (IJV) catheterization was investigated in critically ill pediatric patients to assess the feasibility of the procedure. METHODS Patients admitted to the pediatric intensive care unit between February 2011 and September 2012 were enrolled in this study. All patients received a c...
متن کاملPercutaneous placement of central venous catheters: comparing the anatomical landmark method with the radiologically guided technique for central venous catheterization through the internal jugular vein in emergent hemodialysis patients.
PURPOSE To compare the success and immediate complication rates of the anatomical landmark method (group 1) and the radiologically (combined real-time ultrasound and fluoroscopy) guided technique (group 2) in the placement of central venous catheters in emergent hemodialysis patients. MATERIAL AND METHODS The study was performed prospectively in a randomized manner. The success and immediate ...
متن کاملThe real effectiveness of ultrasound guidance in subclavian venous access.
AIM The technique of ultrasound-guided subclavian cannulation was evaluated in our experience assessing the real effectiveness of such procedure. METHODS We have evaluated 297 subclavian cannulation, performed for the placement of central venous catheter both with landmark method (176 patients) and ultrasound guided technique (121 patients) to assess the real effectiveness of the ultrasound-g...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Anesthesiology
دوره 108 6 شماره
صفحات -
تاریخ انتشار 2008