Cyromazine imprinted polymers for selective stir bar sorptive extraction of melamine in animal feed and milk samples.

نویسندگان

  • Wenying Fan
  • Mingqi Gao
  • Man He
  • Beibei Chen
  • Bin Hu
چکیده

In this work, a molecularly imprinted polymer (MIP) coated stir bar was prepared using a self-designed polytetrafluoroethylene (PTFE) mold and in situ polymerization, with cyromazine as the dummy template for the target melamine. The prepared MIP coated stir bar presented a uniform and porous surface as well as good chemical stability and selectivity for melamine. Based on it, a method of MIP coated stir bar sorptive extraction (SBSE) combined with high performance liquid chromatography-ultraviolet detection (HPLC-UV) was developed for the quantification of melamine in food samples. Significant factors affecting the extraction efficiency of melamine by MIP-SBSE, such as the extraction solvent and time, stirring rate, desorption solvent and time, were investigated thoroughly. Under the optimal conditions, the analytical performance of this method was evaluated. The detection limit of the developed method was 0.54 μg L(-1) for melamine with an enrichment factor of 42-fold and the relative standard deviation (RSD) of 6.1% (c = 5 μg L(-1), n = 7), and the linear range was 2-200 μg L(-1). The established method was applied for the determination of melamine in a variety of real samples including cat food, dog food, chicken feed A, chicken feed B and milk powder, and the recoveries for melamine in the spiked samples were in the range of 76.2-98.2%, 80.0-85.5%, 89.5-113%, 85.0-95.5% and 65.0-111%, respectively. The proposed method presented a good specific recognition ability and matrix interference resistance, and was demonstrated to be effective and sensitive for the analysis of melamine in animal food and milk samples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Molecularly Imprinted Stir Bar Sorptive Extraction Coupled with High-Performance Liquid Chromatography for Trace Analysis of Diclofenac in Different Real Samples

A novel molecularly imprinted polymer-coated stir bar has been used to selectively extract diclofenac (DFC) directly from real samples. DFC was used as template molecule for preparation of MIP coating. The effect of different parameters on the extraction efficiency were studied and the optimum conditions were established as: the absorption and desorption times were fixed at 10 min, stirring...

متن کامل

Molecularly imprinted stir bar sorptive extraction coupled with high performance liquid chromatography for trace analysis of sulfa drugs in complex samples.

A novel sulfamethazine molecularly imprinted polymer (MIP)-coated stir bar for sorptive extraction of eight sulfa drugs from biological samples was prepared. The MIP-coating was about 20 μm thickness with the relative standard deviation (RSD) of 6.7% (n=10). It was characterized by scanning electron microscope, infrared spectrum, thermogravimetric analysis, and solvent-resistant investigation, ...

متن کامل

Sample Preparation in Bio Analytical Methods - a Review

This article reviews the recent developments in Bio-Analytical sample preparation techniques and gives an update on basic principles, Applications and comparative discussion on the advantages and limitations of each technique. Conventional Solid-Phase Extraction (SPE), Molecularly Imprinted Polymer SPE techniques are have been considered as methods of past. Developments in SPE techniques such a...

متن کامل

Molecularly imprinted monolith coupled on-line with high performance liquid chromatography for simultaneous quantitative determination of cyromazine and melamine.

We report a novel method for simultaneous determination of cyromazine and melamine based on a molecularly imprinted monolith on-line coupled with high performance liquid chromatography (HPLC). The imprinted monolith was prepared by in situ polymerization using 2,4-diamino-6-undecyl-1,3,5-triazine (DAUTA) as a mimic template. Due to the better solubility of DAUTA in chloroform, hydrogen bonds we...

متن کامل

High-performance liquid chromatographic method for the determination of cyromazine and melamine residues in milk and pork.

A high-performance liquid chromatography method is described in this paper. The method uses NH(2) column and 97% acetonitrile eluate to determine the insecticide cyromazine and metabolite melamine residues in milk and pork. Samples were treated with NaOH and extracted with acetonitrile containing 20% NH(4)OH. Target analytes of samples were cleaned up and concentrated by C(18) column solid-phas...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Analyst

دوره 140 12  شماره 

صفحات  -