Catheter patency and function after catheter sheath disruption: a pilot study.

نویسندگان

  • Matthew J Oliver
  • David C Mendelssohn
  • Robert R Quinn
  • Elizabeth P Richardson
  • Deeraj K Rajan
  • Robyn A Pugash
  • Joyce A Hiller
  • Alex J Kiss
  • Charmaine E Lok
چکیده

BACKGROUND AND OBJECTIVES Hemodialysis catheters are frequently complicated by dysfunction from fibrin sheaths. Previous studies of sheath disruption have methodologic limitations but suggest that the patency after disruption is short. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS A randomized, controlled, pilot trial was conducted to investigate the impact of angioplasty sheath disruption on catheter patency and function. Forty-seven long-term hemodialysis patients with secondary, refractory catheter dysfunction underwent guidewire exchange to replace their catheters. RESULTS Sheaths were present in 33 (70%) of the 47 patients. In 18 patients who were randomly assigned to disruption, the median time to repeat dysfunction was 373 d compared with 97.5 d in patients who did not undergo disruption (P = 0.22), and the median time to repeat catheter exchange was 411 and 198 d, respectively (P = 0.17). Mean blood flow (340 versus 329 ml/min; P < 0.001) and urea reduction ratio (72 versus 66%; P < 0.001) were higher in the disruption group. Fourteen patients had no sheaths, and their median times to repeat dysfunction and repeat exchange were 849 and 879 d, respectively. Patients with no sheaths had higher urea reduction ratio (73 versus 66%; P < 0.001) and a lower percentage of inadequate hemodialysis treatments (9.8 versus 27%; P = 0.01) and treatments that required thrombolytics (1.8 versus 5.0%; P = 0.03) than patients with sheaths that were not disrupted. CONCLUSIONS Disrupting sheaths by angioplasty balloon results in durable catheter patency and modestly improves blood flow and clearance over the duration of catheter use.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dialysis catheter fibrin sheath stripping: a useful technique after failed catheter exchange

Fibrin sheath formation around long-term haemodialysis catheter is a common cause of failed dialysis access. Treatment options include pharmacological and mechanical methods. This paper reports a case of failed dialysis access due to fibrin sheath encasement. Pharmacologic thrombolysis, mechanical disruption using guide wire and catheter exchange had failed to address the issue. Eventually, fib...

متن کامل

Percutaneous fibrin sleeve stripping of failing haemodialysis catheters.

BACKGROUND One of the most frequent reasons for failure of haemodialysis lines is catheter blockage caused by fibrin sheath formation. We report our experience of percutaneous fibrin sheath stripping in treating this problem. METHODS A consecutive series of failing haemodialysis catheters underwent percutaneous fibrin sheath stripping in an attempt to retrieve and prolong the life of the cath...

متن کامل

Impact of catheter insertion using the radial approach on vasodilatation in humans.

The aim of this study was to determine the impact of catheter sheath insertion, a model of endothelium disruption in humans, on the conventional FMD (flow-mediated dilatation) response in vivo. Seventeen subjects undergoing transradial catheterization were recruited and assessed prior to, the day after, and 3-4 months postcatheterization. The catheter sheath's external diameter was 2.7 mm, and ...

متن کامل

Comparing the early function and complications between fluoroscopic guidance and blindly insertion of permanent hemodialysis catheter

Objective: Chronic kidney disease (CKD) is a complicated kidney defect causing permanent failure in renal function in progressive stages. Hemodialysis is the most accepted treatment to maintain body’s fluid/electrolyte homeostasis at the terminal stages of the disease. Permanent hemodialysis catheter (permicath) may be inserted blindly or by fluoroscopic guidance. This study aimed to compare th...

متن کامل

Fibrin sheath removal from central venous catheters: an internal snare manoeuvre.

BACKGROUND Dysfunction of haemodialysis catheters is most commonly due to a narrowing of the catheter lumen and/or formation of a fibrin sheath around the catheter tip. Reported methods for restoring patency of the catheter lumen include passage of a J-tipped guide wire, passage of a biopsy brush through the catheter, or infusion of a thrombolytic agent into the catheter. While these methods ar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical journal of the American Society of Nephrology : CJASN

دوره 2 6  شماره 

صفحات  -

تاریخ انتشار 2007