Increased frequency dependence of specific airway resistance in patients with laryngeal hemiplegia.
نویسندگان
چکیده
The aim of this study was to investigate whether patients with laryngeal hemiplegia (LH) show a frequency-dependent increase in specific airway resistance (sRaw), measured by body plethysmography. In addition to the flow-volume loop, usually considered in the functional evaluation of upper airway obstructions, variations in sRaw at respiratory frequencies of 30+/-5 (=0.5 Hz), 60+/-5 (=1 Hz) and 90+5 breaths x min(-1) (=1.5 Hz) in 21 never-smoking patients (LH group, mean age+/-SD 55+/-12.09 yrs; 17 females) whose unilateral vocal-cord paralysis was documented by laryngoscopy and who had no signs or symptoms of other respiratory diseases studied. They were compared to 21 healthy control subjects (C group: 50.1+/-15.44 yrs; 10 females). The sRaw values at 30+/-5 breaths min(-1) were similar in the two groups (5.54+/-1.88 versus 5.68+/-1.06 cmH2O x s(-1); p=NS), but at increasing frequencies (30+/-5, 60+/-5 and 90+/-5 breaths min(-1)), they progressively and significantly increased in the LH patients (from 5.54+/-1.88 to 6.63+/-1.96 and 8.05+/-2.6 mH2O x s(-1); p<0.0005), and not significantly in controls (5.68+/-1.06, 5.85+/-0.95 and 5.9+/-1.12 cmH2O x s(-1); p=NS). Linear discriminant analysis using AsRaw (sRaw at 1.5 Hz-sRaw at 0.5 Hz) and forced inspiratory flow at 50% of the vital capacity made it possible to correctly classify all of the controls and 19 of the 21 patients. In conclusion, the multiple, rapid and noninvasive plethysmographical testing of frequency-dependent increase in specific airway resistance with the flow-volume loop, allows the sufficiently satisfactory discrimination of laryngeal hemiplegia patients from controls.
منابع مشابه
مقایسه مقاومت و کمپلیانس دینامیک راه هوایی بین لوله تراشه کافدار و لوله لارنژیال در بیهوشی داخل وریدی کامل(TIVA) Comparing Air Way Resistance and Dynamic Compliance of Tracheal Tube and Laryngeal Tube in TIVA
Background & Aim: The aim of this study was to compare air way resistance and dynamic compliance of tracheal tube and laryngeal tube in TIVA(Total Intravenous Anesthesia). Nowadays, low airway resistance and dynamic compliance improvement during the mechanical ventilation whether in ICU or during general anesthesia, especially in patients with pulmonary diseases, is a favorable purpose to c...
متن کاملSafe Use of Flammable Endotracheal Tubes During Anesthesia for Laryngeal Laser Surgery-Report of 1024 Cases and a Brief Literature Review
Introduction: One of the major concerns in laryngeal laser surgery is the risk of airway fire. The introduction ofwrapped tubes and metal tubes has reduced the fire hazards. However, these tubes are expensive and do not provide convenient access to the surgical field. There are few laboratory studies addressing the resistance of polyvinylchloride tubes against ignition in the given circum...
متن کاملHemodynamic responses to insertion of the laryngeal mask airway versus Combitube
Introduction: One of the most common problems during laryngoscopy involves sympathetic system stimulation and the subsequent hemodynamic changes. It is a key measure to maintain the hemodynamic stability of patients with cardiovascular diseases during induction of anesthesia. This study attempted to compare the hemodynamic effects of laryngeal mask airway and combitube. Methods: This prospec...
متن کاملComparison of the Incidence of Sore Throat and Hemodynamic Changes in Airway Management by Macintosh, Glideoscope Laryngoscope and Laryngeal Mask Airway Techniques: Randomized Controlled Trial
Background: Studies have shown that postoperative sore throat is the most common complication of tracheal intubation, However, the actual incidence and extent of it are not well documented. Objective: The aim of this study was to evaluate and compare the incidence of sore throat and hemodynamic Changes in Macintosh, Glidescope Laryngoscope and laryngeal mask airway techniques in elective surg...
متن کاملمقایسه تاثیر لوله گذاری داخل نای و جاگذاری ماسک حنجره بر فشار داخل چشمی
Background and purpose: control of intraocular pressure has specific role in ophthalmic surgery but ËTT as a common access to airway in general anesthesia lead to increase in ÏÔP, so, many study have been done to evaluate an alternative access to airway such as laryngeal mask. We conducted this study to evaluate intraocular pressure changes subsequent to insertion of laryngeal mask airway and...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The European respiratory journal
دوره 18 6 شماره
صفحات -
تاریخ انتشار 2001