Resolution of an apparent hook effect in Roche partner DRI oxycodone immunoassay.
نویسندگان
چکیده
A presumed hook effect in the semiquantitative DRI Oxycodone immunoassay, OXY3S (Cobas Integra, Roche Diagnostics), was investigated in 14 urine samples with gas chromatography/mass spectrometry (GC-MS) >10,000 ng/mL but OXY3S <1,000 ng/mL. These samples included the index case, a false-negative OXY3S result with >75,000 ng/mL oxycodone + oxymorphone by GC-MS confirmation. Patient samples needed 2- to 16-fold dilution to obtain the correct OXY3S response. The OXY3S test did not hook at high-spiked concentrations of oxycodone, oxymorphone or oxymorphone-3β-d-glucuronide in drug-free urine. The OXY3S test parameters were replicated in a development channel on the Cobas using DRI Reagents (Microgenics, CA, USA) and were subsequently modified. Delayed sample addition or doubling of Reagent 1 (R1: antibody/substrate/co-factor) yielded maximal immunoassay response (>10,000 ng/mL) in 12 of 14 and 14 of 14 undiluted patient samples, respectively. Supplementation of R1 with substrate alone did not correctly recover oxycodone from any of the samples, while co-factor supplementation resulted a maximal OXY3S response in 13 of 14 samples. The remaining (index) sample could only be corrected by supplemental R1. The semiquantitative utility of the DRI Oxycodone assay is questionable. Although the precise cause of the under-recovery could not be determined, the modification presented permits reliable oxycodone determination at the high concentrations frequently seen in clinical urine samples.
منابع مشابه
Determination of designer drug cross-reactivity on five commercial immunoassay screening kits.
The detection of new designer drugs is often a difficult issue in forensic urine drug testing as immunoassays are the primary screening methodology for drugs of abuse in many of these laboratories. Cross-reactivity of compounds with immunoassay kits can either aid or complicate the detection of a variety of drug and drug metabolites. For instance, emerging designer drugs that share structural s...
متن کاملA simple homemade apparatus for real-time visualization of nucleic acid electrophoresis that saves time, optimizes separation, and reduces chemical risk.
say to prevent false accusations against patients taking Suboxone. Urine from these patients may produce positive results in oxycodone assays at low cutoff concentrations because of the presence of a combination of naloxone and unidentified compounds. A noteworthy finding is that if the cutoff concentration of the oxycodone assay had been raised from 100 g/L to 300 g/L, only 2 patients (5%) tes...
متن کاملMass Tort Mania The Effect of Saturation Advertising on Claims , Courts
54 ■ For The Defense ■ April 2017 ■ Michael Crist is a partner at DLD Lawyers with over 27 years of experience in product liability, toxic tort, and insurance defense litigation. He has been a member of trial teams in multiple states and has served as national coordinating and trial counsel. Mr. Crist has presented seminars and authored articles on a variety of topics and is a member of DRI. Ma...
متن کاملThe detection of oxycodone in meconium specimens.
A procedure for the determination of oxycodone in meconium using direct ELISA microplate technology followed by electron impact gas chromatography-mass spectrometry (GC-MS) is described for the first time. The abuse of oxycodone (OxyContin) has been widely discussed in mainstream media, and it has been described as a cheap form of heroin. Oxycodone has been reported as having a high degree of a...
متن کاملEvaluation of a new immunoassay for urinary ethyl glucuronide testing.
AIMS The minor ethanol metabolite ethyl glucuronide (EtG) is used as a sensitive and specific test for recent alcohol consumption with clinical and forensic applications. This study evaluated a new enzyme immunoassay (DRI-EtG EIA, Microgenics Corp.) for determination of the EtG concentration in urine samples. METHODS Evaluation was done using the kit calibrators (range 0-5.0 mg/L) and control...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of analytical toxicology
دوره 37 6 شماره
صفحات -
تاریخ انتشار 2013