[Rupture and migration of a reservoir catheter in the subclavian vein].
نویسندگان
چکیده
The patient was a 66-year-old woman with breast cancer who had undergone chemotherapy. She had had a subcutaneous venous catheter implanted through the left subclavian vein six months earlier. She came to the Emergency Department due to sharp pain in the left hemithorax that radiated towards the shoulder. Physical examination was normal. Chest radiography (Fig. 1) showed that the reservoir catheter had broken and migrated due to the compression between the collar bone and first rib. The tube was extracted using a Dormia catheter and the reservoir port was withdrawn. c i r e s p . 2 0 1 4 ; 9 2 ( 2 ) : 1 2 6
منابع مشابه
The Impact of Intraluminal Vancomycin Adminstration on Prevention of Hemodialysis CatheterRelated Infections
Introduction: Percutaneously inserted double-lumen central venous hemodialysis catheters provide the nephrologist with an excellent temporary access for an immediate hemodialysis treatment and preserve the peripheral veins for the future creation of a permanent arteriovenous vascular access. Unfortunately catheterrelated infections are usually common. In this study, the impact of intra luminal ...
متن کاملRemoval of an Umbilical Catheter Migrated into the Neck in a Neonate: Report of Case
Umbilical and supraumbilical catheter insertion is a common procedure performed in the NICU. It is a safe and usually easy procedure devoid of serious mishaps, morbidity and mortality. Complications such as hemorrhage, infection, hernia, evisceration, omphalitis, portal vein thrombosis and portal hypertension may occur after umbilical catheter insertion. Other uncommon and rare complications re...
متن کاملA catheter malpositioned patient with pain and paresthesia
We report a 54-year-old woman with the history of end-stage renal disease (ESRD) who was admitted to our hospital because of volume overload. Due to long-term use of peripheral veins and arteriovenous fistula (AVF) failure, central venous catheterization was the only choice for hemodialysis. She developed right upper extremiti’s pain and paresis during hemodialysis. A posteroanterior chest x-ra...
متن کاملHandling measures for the implantable vascular access device to prevent of catheter fracture/disruption
This study aims to investigate the causes of catheter fracture and handling measures for implantable vascular access devices to prevent catheter fracture. We retrospectively examined 3088 adult patients with catheter fracture/disruption caused by totally implantable vascular access devices (TIVDs). In the 3088 cases, implantation was via the internal jugular vein in 2909 cases and the subclavia...
متن کاملShould a Double-Lumen Catheter be withdrawn?
Haemodialysis needs a credible and recurrent access to the systemic circulation which can be accomplished by way of central vein catheterization. We report the case of bleeding after withdrawal of the double lumen catheter. A 36-year-old woman who was a known case of end-stage renal disease referred to a dialysis center because of her arteriovenous fistula malfunction. A double-lumen catheter w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Cirugia espanola
دوره 92 2 شماره
صفحات -
تاریخ انتشار 2014