Impedance-based Structural Health Monitoring

نویسندگان

  • Gyuhae Park
  • Daniel J. Inman
چکیده

1. Introduction The development of a real-time, in-service structural health monitoring and damage detection technique has recently attracted a large number of academic and industrial researchers. The goal of this research is to allow systems and structures to monitor their own integrity while in operation and throughout their lives in order to prevent catastrophic failures and to reduce the costs by minimizing explicit preemptory maintenance and inspection tasks. Impedance-based structural health monitoring techniques have been developed by utilizing the electromechanical coupling property of piezoelectric materials (Sun, et al. 1995) and form a new nondestructive evaluation (NDE) method. The basic concept of this approach is to monitor the variations in structural mechanical impedance caused by the presence of damage. Since structural mechanical impedance measurements are difficult to obtain, impedance methods utilize the electrical impedance of piezoelectric materials, which is directly related to the mechanical impedance of the host structure, and will be affected by the presence of structural damage. Through monitoring the measured electrical impedance and comparing it to a baseline measurement, one can qualitatively determine that structural damage has occurred or is imminent. In order to ensure high sensitivity to incipient damage, the electrical impedance is measured at high frequencies (typically greater than 30 kHz). At such high frequencies, the wavelength of the excitation is small and is sensitive enough to detect minor changes in the structural integrity. More importantly, high-frequency (kilohertz) signals require very low voltage (less than 1 volt at micro Watts) to produce a useful impedance excitation in the host structure. By integrating the impedance technique with self-sensing smart materials (Dosch et al. 1992), it has been demonstrated that the impedance-based method is suitable for use in a wide variety of structural health monitoring applications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Thermo-Electro Mechanical Impedance based Structural Health Monitoring: Euler- Bernoulli Beam Modeling

In recent years, impedance measurement method by piezoelectric (PZT) wafer activesensor (PWAS) has been widely adopted for non-destructive evaluation (NDE). In this method, theelectrical impedance of a bonded PWAS is used to detect a structural defect. The electro-mechanicalcoupling of PZT materials constructs the original principle of this method. Accordingly, the electricalimpedance of PWAS c...

متن کامل

0.18 μm CMOS integrated circuit design for impedance-based structural health monitoring

Piezoelectric materials constitute a class of intelligent materials that are helpful for monitoring the structural integrity. The principle of the piezoelectric impedance-based structural health monitoring technique is to measure the electrical impedance of a piezoelectric patch attached to a structure in a certain frequency range. Electrical impedance variations indicate physical changes in th...

متن کامل

Development of DSP-based Electromechanical (E/M) Impedance Analyzer for Active Structural Health Monitoring

The electromechanical (E/M) impedance method is a powerful technique in active structural health monitoring (SHM). E/M impedance method utilizes as its main apparatus an impedance analyzer that reads the in-situ E/M impedance of piezoelectric wafer active sensors (PWAS) attached to the monitored structure. Present-day impedance analyzer equipments (e.g.HP4194) are bulky, heavy and expensive lab...

متن کامل

Refinements of the Impedance-based Structural Health Monitoring Technique

The objective of this chapter is to examine and obtain a better understanding of practical issues that are a result of monitoring the health of structures in an uncontrolled field environment. The effects of external boundary and environmental condition changes and other structural variations on the impedance-based health monitoring technique are investigated. Examples of the factors that consi...

متن کامل

A Circuit Design for Remote Structural Health Monitoring

Intelligent piezoelectric materials are helpful for monitoring the structural health. The principle of the piezoelectric impedance-based structural health monitoring (SHM) technique is to measure the electrical impedance of a piezoelectric patch attached to a structure in a certain frequency range. Electrical impedance variations indicate physical changes in the structure indirectly due to coup...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006