Segmentation and quantification of bone erosions in high-resolution peripheral quantitative computed tomography datasets of the metacarpophalangeal joints of patients with rheumatoid arthritis.

نویسندگان

  • Dominique Töpfer
  • Stephanie Finzel
  • Oleg Museyko
  • Georg Schett
  • Klaus Engelke
چکیده

OBJECTIVE To develop a precise three-dimensional (3D) segmentation technique for bone erosions in high-resolution peripheral quantitative CT (HR-pQCT) datasets to measure their volume, surface area and shape parameters. Assessment of bone erosions in patients with RA is important for diagnosis and evaluation of treatment efficacy. HR-pQCT allows quantifying periarticular bone loss in arthritis. METHODS HR-pQCT scans with a spatial resolution of about 120 µm of the second to fourth metacarpophalangeal joints were acquired in patients with RA. Erosions were identified by placing a seed point in each of them. After applying 3D segmentation, the volume, surface area and sphericity of erosions were calculated. Results were compared with an approximation method using manual measurements. Intra- and interoperator precision analysis was performed for both the 3D segmentation and the manual technique. RESULTS Forty-three erosions were assessed in 18 datasets. Intra- and interoperator precisions (RMSCV/RMSSD) for erosion volume were 5.66%/0.49 mm(3) and 7.76%/0.76 mm(3), respectively. The correlation between manual measurements and their simulation using segmentation volumes was r = 0.87. Precision errors for the manual method were 15.39% and 0.36 mm(3), respectively. CONCLUSION We developed a new precise 3D segmentation technique for quantification of bone erosions in HR-pQCT datasets that correlates to the volume, shape and surface area of the erosion. The technique allows fast and effective measurement of the erosion size and could therefore be helpful for rapid and quantitative assessment of erosion size.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ultrasonography detection of early bone erosions in the metacarpophalangeal joints of patients with rheumatoid arthritis.

OBJECTIVE To compare ultrasonography (US) and magnetic resonance imaging (MRI) in their capability to detect bone erosions in early-advanced rheumatoid arthritis, where no erosion was evident on conventional radiography (X-ray). METHODS Metacarpophalangeal (MCP), radiocarpal and ulnocarpal joints of 13 patients with rheumatoid arthritis, with bone erosion that was not detected by conventional...

متن کامل

Are bone erosions detected by magnetic resonance imaging and ultrasonography true erosions? A comparison with computed tomography in rheumatoid arthritis metacarpophalangeal joints

The objective of the study was, with multidetector computed tomography (CT) as the reference method, to determine whether bone erosions in rheumatoid arthritis (RA) metacarpophalangeal (MCP) joints detected with magnetic resonance imaging (MRI) and ultrasonography (US), but not with radiography, represent true erosive changes. We included 17 RA patients with at least one, previously detected, r...

متن کامل

Automated three-dimensional registration of high-resolution peripheral quantitative computed tomography data to quantify size and shape changes of arthritic bone erosions.

OBJECTIVE To monitor size and shape changes of bone erosions and changes in BMD in the vicinity of the erosion and in the periarticular trabecular compartment of patients with RA using high-resolution peripheral quantitative CT (HR-pQCT) imaging and to compare an automated three-dimensional (3D) image processing technique with manual measurements of erosion width and depth. METHODS The shape ...

متن کامل

Ultrasonographic assessment of bone erosions in the different subtypes of systemic lupus erythematosus arthritis: comparison with computed tomography

BACKGROUND The aim was to determine the accuracy of high-resolution ultrasonography (US) for detecting erosion in the metacarpophalangeal (MCP) and wrist joints of patients with different subtypes of systemic lupus erythematosus (SLE) arthritis, using computed tomography (CT) as the gold-standard reference method. METHOD The ulnar head, radiocarpal and second to fifth MCP joints in 26 patient...

متن کامل

Catabolic and anabolic periarticular bone changes in patients with rheumatoid arthritis: a computed tomography study on the role of age, disease duration and bone markers

INTRODUCTION The aim of this study was to determine the factors, including markers of bone resorption and bone formation, which determine catabolic and anabolic periarticular bone changes in patients with rheumatoid arthritis (RA). METHODS Forty RA patients received high-resolution peripheral quantitative computed tomography (HR-pQCT) analysis of the metacarpophalangeal joints II and III of t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Rheumatology

دوره 53 1  شماره 

صفحات  -

تاریخ انتشار 2014