Computerized Simulation of Automotive Air-Conditioning System: Development of Mathematical Model and Its Validation
نویسندگان
چکیده
A semi-empirical model for simulating thermal and energy performance of an automotive air-conditioning (AAC) system in passenger vehicles has been developed. The model consists of two sections, namely empirical evaporator correlations and dynamic load simulation. The correlations used consider sensible and latent heat transfer performance of the evaporator coil. The correlations were obtained from the experimental data of actual air conditioning system for a compact size passenger car. The sensible heat transfer correlation relates the evaporator air off drybulb temperature to inlet air dry-bulb temperature, humidity ratio, evaporator air velocity, condenser inlet air dry-bulb temperature, condenser air velocity and compressor speed. The latent heat transfer correlation relates the coil air-off humidity ratio to the same six independent variables. The dynamic load simulation model was developed based on the z-transfer function method with a one-minute time step. The cooling load calculations were performed using heat gain weighting factors. Heat extraction rate and cabin air dry-bulb temperature calculations were carried out using air temperature weighting factors. The empirical evaporator sensible and latent heat transfer correlations were embedded in the loads calculation program to enable the determination of evaporator inlet and outlet air conditions, the cabin air temperature and relative humidity. Comparisons with road test data indicated that the program was capable of predicting the performance of the automotive air-conditioning system with reasonable accuracy.
منابع مشابه
Evaluation of Transient Refrigerant Migration Modeling Approach on Automotive Air Conditioning Systems
Automotive air conditioning systems are subject to constantly changing operation conditions and steady state simulations are not sufficient to describe the actual performance. The refrigerant mass migration during transient events such as clutch-cycling or start-up bas a direct impact on the transient performance. It is therefore necessary to develop simulation tools which can accurately predic...
متن کاملDesign and operation optimization of an air conditioning system through simulation: an hour-by-hour simulation study
In the present research, performance validation of a Heating, Ventilation, and Air Conditioning (HVAC) system operating in a library building was conducted. The operating HVAC system was studied in terms of the provided indoor air conditions and energy consumption level. The fieldwork measurements showed that the HVAC system is not capable of providing the desired indoor air conditions based on...
متن کاملThermal modeling of mini-channel and laminated Types evaporator in mobile air conditioning system
In this paper, mini-channel type evaporator which is new in mobile air conditioning (MAC) or automotive air conditioning (AAC) systems is thermally modeled. The performance of mini-channel evaporator is also compared with the laminated evaporator which is being currently used in automotive industries. The mini-channel evaporator was constructed of two rows of parallel flow mini-channel tubes...
متن کاملRefrigerant mass migration modeling and simulation for air conditioning systems
Refrigerant mass migration and redistribution are regarded as key factors affecting the cycling perfor mance of air conditioning and refrigeration systems. A dynamic model of an R134a automotive air conditioning system is presented as an example in this paper to capture the refrigerant migration during compressor shut-down and start-up operations. Model validation against experimental data dem...
متن کاملSustainability of Automobile Air- Conditioning System Using Refrigerant R1234yf Instead of R134a
Air conditioning refrigerant R134a has value of global warming potential (GWP) 1300, which is much higher than MAC Directive (GWP below 150) passed in July 2006. This prompted a search for alternative refrigerant with GWP value less than 150. R1234yf is a new refrigerant which has lower GWP value of 4. Effect of blower speed has been compared and flammability issue of R1234yf has been addre...
متن کامل