A review of on-chip micro-evaporation: Experimental evaluation of liquid pumping and vapor compression driven cooling systems and control
نویسندگان
چکیده
Thermal designers of data centers and server manufacturers are showing a greater concern regarding the cooling of the new generation data centers, which consume considerably more electricity and dissipate much more waste heat, a situation that is creating a re-thinking about the most effective cooling systems for the future beyond conventional air cooling of the chips/servers. A potential significantly better solution is to make use of on-chip two-phase cooling, which, besides improving the cooling performance at the chip level, also adds the capability to reuse the waste heat in a convenient manner, since higher evaporating and condensing temperatures of the two-phase cooling system (from 60 to 95 C) are possible with such a new ‘‘green’’ cooling technology. In the present project, two such two-phase cooling cycles using micro-evaporation technology were experimentally evaluated with specific attention being paid to (i) controllability of the two-phase cooling system, (ii) energy consumption and (iii) overall exergetic efficiency. The controllers were evaluated by tracking and disturbance rejection tests, which were shown to be efficient and effective. The average temperatures of the chips were maintained below the limit of 85 C for all tests evaluated in steady state and transient conditions. In general, simple SISO strategies were sufficient to attain the requirements of control. Regarding energy and exergy analyses, the experimental results showed that both systems can be thermodynamically improved since only about 10% of the exergy supplied is in fact recovered in the condenser in the present setup. 2011 Elsevier Ltd. All rights reserved.
منابع مشابه
Superstructure of Cogeneration of Power, Heating, Cooling and Liquid Fuels Using Gasification of Feedstock with Primary Material of Coal for Employing in LNG Process
Using absorption refrigeration cycles instead of vapor compression refrigeration cycles can drastically decrease energy consumption. In these systems, high level of energy consumption is reduced due to the partially elimination of vapor compression refrigeration systems. On the other hand, utilization of waste heat of the plant, which is a very good opportunity for energy saving, is possible. ...
متن کاملDevelopment of a chip-integrated micro cooling device
An experimental/computation investigation was carried out to develop a MEMS-based micro cooling device to provide direct cooling to high heat flux electronics and MEMS devices. This device uses the electrohydrodynamic principles to pump and form an ultra thin film over a heated surface that requires cooling. The important part is played by applying an electric field to a set of interdigitated i...
متن کاملMems - Based Thermal Management of High Heat Flux Devices Edifice : Embedded Droplet Impingement for Integrated Cooling
Increases in microprocessor power dissipation coupled with reductions in feature sizes due to manufacturing process improvements have resulted in continuously increasing heat fluxes. The ever increasing chip-level heat flux has necessitated the development of thermal management devices based on spray and evaporative cooling. This lecture presents a comprehensive review of liquid and evaporative...
متن کاملLiquid metal cooling in thermal management of computer chips
With the rapid improvement of computer performance, tremendous heat generation in the chip becomes a major serious concern for thermal management. Meanwhile, CPU chips are becoming smaller and smaller with almost no room for the heat to escape. The total power-dissipation levels now reside on the order of 100 W with a peak power density of 400–500 W/cm2, and are still steadily climbing. As a re...
متن کاملA More Accurate Prediction of Liquid Evaporation Flux
In this work, a more accurate prediction of liquid evaporation flux has been achieved. The statistical rate theory approach, which is recently introduced by Ward and Fang and exact estimation of vapor pressure in the layer adjacent to the liquid–vapor interface have been used for prediction of this flux. Firstly, the existence of an equilibrium layer adjacent to the liquid-vapor interface ...
متن کامل