High-numerical-aperture-based virtual point detectors for photoacoustic tomography.

نویسندگان

  • Changhui Li
  • Lihong V Wang
چکیده

The focal point of a high-numerical-aperture (NA) ultrasonic transducer can be used as a virtual point detector. This virtual point detector detects omnidirectionally over a wide acceptance angle. It also combines a large active transducer surface and a small effective virtual detector size. Thus the sensitivity is high compared with that of a real point detector, and the aperture effect is small compared with that of a finite size transducer. We present two kinds of high-NA-based virtual point detectors and their successful application in photoacoustic tomography. They can also be applied in other ultrasound-related fields.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Photoacoustic tomography of the mouse cerebral cortex with a high-numerical-aperture-based virtual point detector.

The mouse cerebral cortex was imaged in situ by photoacoustic tomography (PAT). Instead of a flat ultrasonic transducer, a virtual point detector based on a high numerical aperture (NA), positively focused transducer was used. This virtual point detector has a wide omnidirectional acceptance angle, a high sensitivity, and a negligible aperture effect. In addition, the virtual point detector can...

متن کامل

Photoacoustic tomography of a rat cerebral cortex with a ring-based ultrasonic virtual point detector.

We image a rat cerebral cortex in situ by using a ring-based ultrasonic virtual point detector developed previously. Compared to the image generated by a finite-aperture detector, the image generated by the virtual point detector has a uniformly distributed resolution throughout the imaged area, owing to the lack of aperture effect of the ultrasonic detector. At the periphery of the image, the ...

متن کامل

Improving tangential resolution with a modified delay-and-sum reconstruction algorithm in photoacoustic and thermoacoustic tomography.

Spatial resolution in photoacoustic and thermoacoustic tomography is ultrasound transducer (detector) bandwidth limited. For a circular scanning geometry the axial (radial) resolution is not affected by the detector aperture, but the tangential (lateral) resolution is highly dependent on the aperture size, and it is also spatially varying (depending on the location relative to the scanning cent...

متن کامل

Improved in vivo photoacoustic microscopy based on a virtual-detector concept.

Recently an in vivo high-resolution backward-mode photoacoustic microscope was developed that shows potential for applications in dermatology and related cancer research. However, the limited depth of focus of the large-numerical-aperture (NA) ultrasonic lens employed in this system causes the image quality to deteriorate significantly in the out-of-focus region. To solve this problem, we devis...

متن کامل

Weight factors for limited angle photoacoustic tomography.

Photoacoustic tomography (PAT) is based on the generation of ultrasound waves by heating an object with short light pulses. A three-dimensional image of the distribution of absorbed energy within the object is reconstructed from signals measured around the object with either point-like or extended, linear sensors. Limited angle artefacts arise when the curve or surface connecting neighbouring d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied physics letters

دوره 93 3  شماره 

صفحات  -

تاریخ انتشار 2008